QuickSpecs

Technical Specifications

Operating Temperature
Operating Temperature
Operating Temperature
Operating Temperature
Shipping Temperature
Shipping Temperature
Shipping Temperature
Shipping Temperature
Humidity
Humidity
Humidity
Humidity
Shipping Humidity
Shipping Humidity
Shipping Humidity
Shipping Humidity
Altitude
Altitude
Altitude
Altitude
Air Quality
Air Quality
Air Quality
Air Quality
Power Data maximum configuration
Power Data
Power Data
Power Data
maximum configuration
maximum configuration
maximum configuration
AC plug type
AC plug type
AC plug type
AC plug type
(quantity 2)
Number of phases
Number of phases
Number of phases
Number of phases
Rated current
Rated current
Rated current
Rated current
Nominal Line Voltage
Nominal Line Voltage
Nominal Line Voltage
Nominal Line Voltage
Range Line Voltage
Range Line Voltage
Range Line Voltage
Range Line Voltage
Line Frequency
Line Frequency
Line Frequency
Line Frequency
Enterprise Virtual Array 4400
Enterprise Virtual Array 4400
Enterprise Virtual Array 4400
Enterprise Virtual Array 4400
NOTE: This data represents fully
NOTE:
NOTE:
NOTE:
populated drive shelves with 15K
rpm disk drives under typical
performance. Other drive types may
vary slightly. Note, at idle, the
system operates at approx. 15% less
power than at typical.
Typical
Typical Total System Wattage
Total System Wattage
Typical
Typical
Total System Wattage
Total System Wattage
Total System BTU/hour
Total System BTU/hour
Total System BTU/hour
Total System BTU/hour
Input Current (A)-Typical
Input Current (A)-Typical
Input Current (A)-Typical
Input Current (A)-Typical
per system
per system
per system
per system
In Rush Current (A)
In Rush Current (A)
In Rush Current (A)
In Rush Current (A)
Failover
Failover
Failover
Failover
Input Current (A)-
Input Current (A)-
Input Current (A)-
Input Current (A)-
Mode
Mode
Mode
Mode
Maximum per system
Maximum per system
Maximum per system
Maximum per system
NOTE:
NOTE:
NOTE:
NOTE: Typical is described as a system in normal steady state operation. (I.e., both PDUs operating normally, the array
reading/writing to disk drives in a production environment)
Enterprise Virtual Array EVA4400 Product Dimensions, Weight and Clearance
Enterprise Virtual Array EVA4400 Product Dimensions, Weight and Clearance
Enterprise Virtual Array EVA4400 Product Dimensions, Weight and Clearance
Enterprise Virtual Array EVA4400 Product Dimensions, Weight and Clearance
50° to 95° F (10° to 35° C) - Reduce rating by 1° F for each 1000 ft altitude (1.8° C/1,000 m)
-40° to 150° F (-40° to 66° C)
10% to 90% non-condensing
5% to 90% non-condensing
Up to 8,000 ft (2,400 m)
Not to exceed 500,000 particles per cubic foot of air at a size of 0.5 micron or larger
3 wire NEMA No. L6-30P, 30 Amp (208 to 240V, 50-60Hz 30A)
Single
17A @ 200V-240V AC, 60Hz total, 4.25 A per power cord
208 or 230V
187 to 256V
60 Hz
2C1D
2C1D
2C1D
2C1D
2C2D
2C2D
2C2D
2C2D
424
728
1447
2485
1.6 / 1.5
2.6 / 2.4
98 /
132 /147 170 / 190 220/244 250 / 272 280 / 311 321 / 357 363 / 403
10498
2.7 / 2.6
4.3 / 4.1
DA - 12893
North America — Version 1 — February 26, 2008
HP StorageWorks 4400 Enterprise Virtual Array
HP StorageWorks 4400 Enterprise Virtual Array
HP StorageWorks 4400 Enterprise Virtual Array
HP StorageWorks 4400 Enterprise Virtual Array
EVA4400
EVA4400
EVA4400
EVA4400
EVA4400
EVA4400
EVA4400
EVA4400
208/230 Volts
208/230 Volts
208/230 Volts
208/230 Volts
2C3D
2C3D
2C3D
2C3D
2C4D
2C4D
2C4D
2C4D
2C5D
2C5D
2C5D
2C5D
1032
1336
1640
3522
4560
5597
3.5 / 3.3
4.4 / 4.3
5.5 / 5.2
5.9/ 5.5
7.57.8 /
9.4 / 8.8 11.0/10.0 12.6/11.9 14.2 /13.7
7.3
2C6D
2C6D
2C6D
2C6D
2C7D
2C7D
2C7D
2C7D
2C8D
2C8D
2C8D
2C8D
1944
2248
2552
6635
7872
8710
6.5 / 6.1
7.4 / 7.0 8.4 / 8.0