No Data Received Reports; Description; No Data Received; Data Error - Bosch Conettix D6600 Installation And Operation Manual

Communications receiver/gateway
Hide thumbs Also See for Conettix D6600:
Table of Contents

Advertisement

Conettix D6600/D6100i | Installation and Operation Guide | 12.0 No Data Received Reports
.
Figure 16: Conettix Network System
Connection Diagram - D9133TTL-
E/DX4020 and Bosch Control Panels
3
2
1
1 2 4 8
15
11
14
1 – Bosch Control Panels
2 – Connection – Control panel serial device
interface (SDI) bus to D9133TTL-E or DX4020
SDI Terminals
3 – D9133TTL-E or DX4020 Network Interface
Module
4 – Connection – D9133TTL-E or DX4020
Ethernet port to Ethernet hub
5 – Host PC running D6200 Programming
Administrative Software
6 – Connection – Ethernet hub to Host PC NIC
7 – Ethernet hub
8 - Connection – Ethernet hub to D6100i
9 - D6100i
10 – Connection – Ethernet hub to D6680
11 – D6680
12 – Connection – D6680 to D6600 COM4 port
13 – D6600
14 – Connection – Second D6680 to D6600 COM1
port (optional)
15 – Connection – Ethernet hub to second D6680
Bosch Security Systems, Inc. | 9/08| 4998122704-04
4
5
6
7
10
9
12
11
13

12.0 No Data Received

Reports
12.1

Description

If a message is garbled (incorrect checksum or
inconsistent message rounds) due to a noisy
telephone line or other difficulty, the receiver
withholds the kiss-off tone. This causes the control
panel to retransmit the same message up to four
times.
12.2
No Data Received
The D6600/D6100i generates the message shown in
Figure 17 if one or more of the following occur:
Telephone line noise causes the data to be
unrecognized.
A control panel sends the data in a format not
recognized by the D6600/D6100i.
A control panel transmitted nothing.

Figure 17: NO DATA RECEIVED Message

12.3 Data Error

Data Error is a function of PSTN. It is an error
condition when the D6600/D6100i receives partial
data, appears on the LCD, and sends the error to a
connected printer.
This occurs when telephone line noise causes data to
be unrecognizable.
12.4

Wrong Data

Wrong Data is a function of the CPU where the PSTN
software sends an invalid signal to the CPU. It only
sends output to the LCD and any connected printer.
27

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Conettix d6100i

Table of Contents