1-1. Connectors and Cable

1-2. Operating Environment

1-3. Checking the Fan Operation

1-1-3. Connector Input/Output Signals

AC IN
AC 100 V to 240 V, 200 W
DC OUT (4P FEMALE)
4
3
_ _ _ _ _ EXT VIEW _ _ _ _ _
Pin No.
Signal
1
GND
2
NC
3
NC
4
DC OUT
DC OUT (5P FEMALE)
1
2
_ _ _ _ _ EXT VIEW _ _ _ _ _
Pin No.
Signal
1
GND
2
NC
3
NC
4
NC
5
DC OUT
DC OUT (3P)
_ _ _ _ _ EXT VIEW _ _ _ _ _
Pin No.
Signal
1
BATT (_) OUT
2
BATT (+) OUT
3
RID IN
1-2 (E)
1
2
Specifications
GND for UNREG
No connection
No connection
+16.4 to +17.0 V, 9 A MAX
3
4
5
Specifications
GND for DC OUT
No connection
+16.4 to +17.0 V, 9 A MAX
1
2
3
Specifications
GND for DC OUT
+16.5 to +16.9 V, 2.2 A MAX
SENS
1-2. Operating Environment
Operating Temperature : 0 dC to +40 dC
_5 dC to +45 dC
Storage Temperature :
Humidity :
No condensation
1-3. Checking the Fan Operation
The unit is provided with a fan. It is designed to run
automatically when temperature of the heat sink inside the
equipment exceeds over 55dC. If there is any doubt that the
fan or fan motor control circuit fails, check the fan opera-
tion as follows.
Equipment Required
. Electric Load
Hewlett-Packard
HP6051A + HP60501B
1. Set the electric load to 9 A in the CC (constant current)
mode.
2. Connect the electric load as follows and make sure that
the fan starts up within ten minutes.
<Connection for 5P terminal>
To
Electric Load
(_)
Lower cover
(+)
AC-DN2B