en | Configuration
After completing setup, click <Save> to save your settings and go back to the previous menu.
Note: In the Detect menu, the Copy function is only valid for the same event type, which
means you cannot copy a channel setup in video loss mode to camera masking mode.
See also
2013.11 | 1.1 | AM18-Q0669
Sensitivity: Set the threshold for motion detection from 1 to 6 (default). The sixth level
has the highest sensitivity.
Period: Click Setup for a new interface screen where you can organize time periods for
detect activation – see Period, page 60.
Anti-dither: Set here a timer for how long the detect alert should stay active after it is first
activated (default is 5 seconds). During this time, the system will activate the alarm
display, alarm output, tour, PTZ, snapshot, channel recording and buzzer (if they are all
selected). An alarm upload and email will also be sent (if selected). If a new alarm is
detected within the anti-dither time, the timer will be reset for the alarm display, alarm
output, tour, PTZ, snapshot, channel recording and buzzer (no new alarm upload or email
are sent).
Alarm out: If an alarm occurred, the system will enable a peripheral alarm device
connected to the selected outputs (default is 1).
Latch: When the 'Anti-dither' time is ended, the alarm output relay you selected in 'Alarm
out' will remain activated for this extra 'latch' period (from 1 to 300 seconds - default is
10). The latch is still valid even if you manually disable the alarm event.
Show message: The system will pop up a message in the local host screen to alert you.
Alarm upload: The system will upload an alarm signal to the network (including a central
alarm location).
Send email: An alert email is sent if an alarm is detected.
PTZ activation: Here you can set PTZ movement when an alarm occurs. See PTZ activation,
page 61.
Delay: Set here an extra timer for channel recording to remain active (from 10 to 300
seconds - default is 10) after the 'Anti dither' time has elapsed.
Tour: Here you can enable a tour function (a sequence of camera views) when an alarm
occurs. The system supports only one-window tour for alarms. See Display, page 63 for
how to pre-select the tour sequence and interval.
Snapshot: Select to snapshoot an image from the chosen camera(s) when an alarm
occurs. For snapshot operation, see Encode, page 39.
Sequence Mon. B: Select both check boxes here to enable a tour function on Monitor B
when there is an alarm signal. The tour sequence will be the same channels as selected
for the Record channel settings (see above).
Buzzer: Select here to activate the buzzer when an alarm occurs.
Sequence Mon B, page 79