Table 2-12 Maintenance Switch (Sw1) Settings Of Ltrk/8 Card; Table 2-13 Caller Id Switch (Sw10-17) Settings Of Ltrk/8 Card; Table 2-14 Led Indications Of Ltrk/8 Card - Panasonic DBS 576 Technical Manual

Section 300 installation
Hide thumbs Also See for DBS 576:
Table of Contents

Advertisement

Chapter 2. System Overview
Table 2-12 and Table 2-14 show the switch settings and LED indications.
Table 2-12. Maintenance switch (SW1) settings of LTRK/8 card
Setting
Description
ON
Card is in closed status, and can be mounted and removed when power is ON. (Send-
ing/receiving of calls is disabled. If this is set while a trunk is in use, sending/receiv-
ing of calls is disabled after the call ends.)
OFF (M-SW)
Normal operation (This switch is set to OFF for normal operation.)
Table 2-13. Caller ID switch (SW10-17) settings of LTRK/8 card
Switch
Setting
SW10
ON
OFF
SW11
ON
OFF
SW12
ON
OFF
SW13
ON
OFF
SW14
ON
OFF
SW15
ON
OFF
SW16
ON
OFF
SW17
ON
OFF
Table 2-14. LED indications of LTRK/8 card
LED indication
LED1 (LINE BUSY)
2-22
Description
Circuit 1 is in loop start mode and does not receive caller ID information.
Circuit 1 is set to receive Caller ID information (requires CID card).
Circuit 2 is in loop start mode and does not receive caller ID information.
Circuit 2 is set to receive Caller ID information (requires CID card).
Circuit 3 is in loop start mode and does not receive caller ID information.
Circuit 3 is set to receive Caller ID information (requires CID card).
Circuit 4 is in loop start mode and does not receive caller ID information.
Circuit 4 is set to receive Caller ID information (requires CID card).
Circuit 5 is in loop start mode and does not receive caller ID information.
Circuit 5 is set to receive Caller ID information (requires CID card).
Circuit 6 is in loop start mode and does not receive caller ID information.
Circuit 6 is set to receive Caller ID information (requires CID card).
Circuit 7 is in loop start mode and does not receive caller ID information.
Circuit 7 is set to receive Caller ID information (requires CID card).
Circuit 8 is in loop start mode and does not receive caller ID information.
Circuit 8 is set to receive Caller ID information (requires CID card).
Description
Turns ON when any trunk on the card is in use.