SPLIT TYPE AIR CONDITIONER
INDOOR UNIT/OUTDOOR UNIT
OUTDOOR UNIT
RAC-51CHA3
RAC-63CHA3
Instruction manual
To obtain the best performance and ensure years of trouble free use, please read this instruction manual completely.
MODEL
RAS-51CHA3/RAC-51CHA3
RAS-63CHA3/RAC-63CHA3
– 1 –
INDOOR UNIT
RAS-51CHA3
RAS-63CHA3
Page 1~26

Advertisement

Table of Contents
loading

Summary of Contents for Hitachi RAS-51CHA3

  • Page 1 SPLIT TYPE AIR CONDITIONER INDOOR UNIT/OUTDOOR UNIT RAS-51CHA3/RAC-51CHA3 RAS-63CHA3/RAC-63CHA3 OUTDOOR UNIT RAC-51CHA3 RAC-63CHA3 Instruction manual To obtain the best performance and ensure years of trouble free use, please read this instruction manual completely. MODEL INDOOR UNIT RAS-51CHA3 RAS-63CHA3 – 1 –...
  • Page 2: Safety Precaution

    SAFETY PRECAUTION Please read the “Safety Precaution” carefully before operating the unit to ensure correct usage of the unit. Pay special attention to signs of “ if not observed strictly, may cause death or serious injury. The “Caution” section contains matters which may result in serious consequences if not observed properly.
  • Page 3 PRECAUTIONS DURING OPERATION The product shall be operated under the manufacturer specification and not for any other intended use. Do not attempt to operate the unit with wet hands, this could cause fatal accident. When operating the unit with burning equipments, regularly ventilate the room to avoid oxygen insufficiency.
  • Page 4: Names And Functions Of Each Part

    NAMES AND FUNCTIONS OF EACH PART INDOOR UNIT OUTDOOR UNIT MODEL NAME AND DIMENSIONS MODEL RAS-51CHA3/RAS-63CHA3 RAC-51CHA3/RAC-63CHA3 Air filter To prevent dust from coming into the indoor unit. (Refer page 21) Front panel Indoor unit indicators Light indicator showing the operating condition.
  • Page 5: Indoor Unit Indicators

    OPERATION INDICATOR AUTO RESTART SWITCH In the event of power failure, the air conditioner will restart automatically in the previously selected mode once the power is restored. In the event of power failure during TIMER operation, the timer will be reset and the unit will begin or stop operating under a new timer setting.
  • Page 6: Names And Functions Of Remote Control Unit

    NAMES AND FUNCTIONS OF REMOTE CONTROL UNIT REMOTE CONTROLLER This controls the operation of the indoor unit. The range of control is about 7 meters. If indoor lighting is controlled electronically, the range of control may be shorter. This unit can be fixed on a wall using the fixture provided. Before fixing it, make sure the indoor unit can be controlled from the remote controller.
  • Page 7: Automatic Operation

    AUTOMATIC OPERATION The device will automatically determine the mode of operation, HEAT, COOL or DEHUMIDIFY depending on the initial room temperature. The selected mode of operation will not change when the room temperature varies. START RESET I Condition of Automatic Operation Initial room temperature (approx.) Over 27°C...
  • Page 8: Heating Operation

    HEATING OPERATION Use the device for heating when the outdoor temperature is under 21°C. When it is too warm (over 21°C), the heating function may not work in order to protect the device. In order to keep reliability of the device, please use this device above –10°C of the outdoor temperature. ˚...
  • Page 9: Dehumidifying Operation

    DEHUMIDIFYING OPERATION Use the device for dehumidifying when the room temperature is over 16°C. When it is under 15°C, the dehumidifying function will not work. ˚ RESET ˚ I Dehumidifying Function When the room temperature is higher than the temperature setting: The device will dehumidify the room, reducing the room temperature to the preset level.
  • Page 10: Cooling Operation

    COOLING OPERATION Use the device for cooling when the outdoor temperature is 21-43°C. If indoor humidity is very high (over 80%), some dew may form on the air outlet grille of the indoor unit. ˚ RESET ˚ Press the FUNCTION selector so that the display indicates (COOL).
  • Page 11: Fan Operation

    FAN OPERATION You can use the device simply as an air circulator. Use this function to dry the interior of the indoor unit at the end of summer. START RESET ... When the AUTO fan speed mode is set in the cooling/heating operation: FAN SPEED (AUTO) For the heating operation For the cooling operation...
  • Page 12: How To Cancel Reservation

    HOW TO SET THE TIMER TIME, DAY, MONTH (current time, day, month) OFF TIMER RESET ON TIMER RESERVE CANCEL ON-Timer ON/OFF-Timer Start Stop G The device will turn on (off) and off (on) at the designated times. G The switching occurs first at the preset time that comes earlier.
  • Page 13 Set the current time with the Press the TIMER control button. (TIME) button. Example: The current time is 1:30 p.m. Set the turn-off time with the TIMER control button. Set the turn-on time with the TIMER control button. Set the turn-on time with the TIMER control button.
  • Page 14: How To Set The Sleep Timer

    HOW TO SET THE SLEEP TIMER Set the current time at first if it is not set before (see the pages for setting the current time). Press the shown below. SLEEP How to Cancel Reservation Point the signal window of the remote controller toward the indoor unit, and press the button.
  • Page 15: Explanation Of The Sleep Timer

    Explanation of the sleep timer The device will control the FAN SPEED and room temperature automatically so as to be quiet and good for people’s health. You can set the sleep timer to turn off after 1, 2, 3 or 7 hours. The FAN SPEED and room temperature will be controlled as shown below.
  • Page 16: Adjusting The Air Deflector

    ADJUSTING THE AIR DEFLECTOR Adjustment of the conditioned air in the upward and downward directions. The horizontal air deflector is automatically set to the proper angle suitable for each operation. The deflector can be swung up and down continuously and also set to the desired angle using the “...
  • Page 17: How To Exchange The Batteries In The Remote Controller

    HOW TO EXCHANGE THE BATTERIES IN THE REMOTE CONTROLLER Remove the cover as shown in the figure and take out the old batteries. Install the new batteries. The direction of the batteries should match the marks in the case. CAUTION 1.
  • Page 18: Suitable Room Temperature

    THE IDEAL WAYS OF OPERATION Suitable Room Temperature Warning Freezing temperature is bad for health and a waste of electric power. Ventilation Caution Do not close the room for a long period of time. Occasionally open the door and windows to allow the entrance of fresh air.
  • Page 19 FOR USER’S INFORMATION The Air Conditioner And The Heat Source In The Room Caution If the amount of heat in the room is above the cooling capability of the air conditioner (for example: more people entering the room, using heating equipments and etc.), the preset room temperature cannot be...
  • Page 20: Attaching The Air Cleansing And Deodorizing Filters

    Type number for this air cleansing filter is <SPX-CFH5>. Please use this number for ordering when you want to renew it. Do not operate the air conditioner without filter. Dust may enter the air conditioner and fault may occur. Claws (4 places) –...
  • Page 21: Maintenance

    MAINTENANCE CAUTION Cleaning and maintenance must be carried out only by qualified service personal. Before cleaning, stop operation and switch off the power supply. AIR FILTER Clean the air filter, as it removes dust inside the room. In case the air filter is full of dust, the air flow will decrease and the cooling capacity will be reduced.
  • Page 22 Washable Front Panel Remove the front panel and wash with clean water. Wash it with a soft sponge. After using neutral detergent, wash thoroughly with clean water. When front panel is not removed, wipe it with a soft dry cloth. Wipe the remote controller thoroughly with a soft dry cloth.
  • Page 23: Regular Inspection

    CAUTION Cleaning and maintenance must be carried out only by qualified service personal. Before cleaning, stop operation and switch off the power supply. MAINTENANCE AT BEGINNING OF LONG OFF PERIOD Run the unit by setting the operation mode to (COOL), the temperature to 32°C and the fan speed to HI for about half a day on a fine day, and dry the whole of the unit.
  • Page 24 When it does not hot well Notes Please contact your sales agent immediately if the air conditioner still fails to operate normally after the above inspections. Inform your agent of the model of your unit, production number, date of installation. Please also inform him regarding the fault.
  • Page 25 The conditions of the local Power Supply Companies are to be observed. Note Avoid to use the room air conditioner for cooling operation when the outside temperature is below 21°C (70°F). The recommended maximum and minimum operating temperatures of the hot and cold sides should be as below: Dry bulb °C...
  • Page 26 MEMO – 26 –...

Table of Contents