Detail Settings

Miscellaneous Settings Page

Use this page to specify various other settings.
Mail
Log messages are emailed to the specified recipient address via
the specified mail forwarding server using the SMTP.
"Mail Server Host"
Specifies the SMTP server.
"Sender's (From) Mail Address"
Specifies the log mail sender.
c
"Max clients" settings for the WebView Livescope viewer
"WebView Livescope protocol"* and "HTTP protocol" are used in connections from
Note
the helper viewer and Java viewer to the camera server. Synchronous "Max clients"
settings for each of these viewers are as follows.
Helper viewer
Set in "Max clients" on p.52 and p.54.
• A maximum of 20 clients can be connected simultaneously with WebView Livescope protocol
• A maximum of 20 clients can be connected simultaneously with HTTP protocol
Java viewer
Set in "Max clients" on p.54.
• A maximum of 20 clients can be connected simultaneously with HTTP protocol
The helper viewer, Java viewer and Web server can each share HTTP protocol
connections. A maximum of 40 HTTP protocol connections can be accessed.
* "WebView Livescope protocol" supports the helper viewer only
54
HTTP Server
"HTTP Port"
Sets the TCP port number for the HTTP.
Enter an integer between 1 and 65535. As
a general rule, No. 80 is used.
"Max Clients"
Sets the number of HTTP connections
that can be made. The maximum number
of connections that can be made is 40.
Enter an integer between 1 and 40. This
sets the maximum number of clients for
the WebView Livescope viewer and the
Web server.
WebView Livescope viewer: because the
Java viewer and helper viewer use 2
HTTP connections , it is possible to
simultaneously connect a maximum of 20
clients when the setting "40" is entered.
"Maximum Idling Time (sec)"
Sets the time-out time for KeepAlive
connections. Enter an integer between 0
and 20. The maximum wait time is 20
seconds.
If you specify 0, KeepAlive connections
are prohibited.
DNS
Sets the domain name server address.
"Name Server Address 1 to 3"
Enter the addresses.
Enter the addresses from the top down. If
you are only registering 1 or 2 addresses,
the remaining fields can be left blank.
c
The log message will be stored on the flash memory card (sold separately).
Even if settings are made for this page, this function will not operate unless a
Note
flash memory card is inserted into the slot on the main unit.
See Chapter 6 ( P.92 ) for log message details.
The log message for external device input (sensor, etc.) is A023. If the "log mail
gather up time" has been set, this message will be sent after a specified waiting time.
e
Log files will be created in the /card/logs directory (a flash card is required to save log messages in
a file). The most recent log file will be saved as "log". The log file size is specified in "Maximum log
Tip
file size" and if the log file exceeds the specified size, back-up files named "log.0..." are created.
Only the number of back-up log files that are specified in "Maximum number of log files (N)" will
remain. These will be listed in the order, "log.0, log.1,..., log.N". For example, if the maximum number
of log files is set to 10, files named "log.0, log.1,..., log.9" will be created in the same directory. The
file named "log.0" is the most recent back-up file (the most recent log file is listed as "log").
`Because log files will be overwritten in order after the number of files specified in "Maximum
number of log files" have been created, maintenance should be carried out periodically.
Click the [OK] button to change the settings. To discard the changes, click the
[Cancel] button. This returns you to the settings title page.
Detail Settings
Log
"Recipient Mail Address"
Specifies the log mail recipient.
"Syslog Server Host"
Sets the Syslog server.
"Maximum Log File Number"
Sets the maximum number of log files
saved. Enter an integer between 1 and 10.
The maximum number is 10.
"Maximum Log File Size (K bytes)"
Sets the maximum log file size. Enter an
integer between 16 and 1024. The
maximum size is 1024 KB.
"Log mail collection time (min.)"
Log
messages
containing
errors,
warnings and other information are
collected for a set period beginning from
the first log entry. This setting specifies
that collection period. Enter an integer
3
between 0 and 60. The maximum time is
60 minutes.
"Response to Error/Warning/Information"
Tick the "File" option to save log
messages to files.
Tick the "Forward" option to send the
log messages to a Syslog server.
Tick the "Mail" option to send the log
messages by email.