INSTALLATION
AND
SERVICE
MUST
BE PERFORMED
BY
A QUALIFIED
INSTALLER.
IMPORTANT:
SAVE
FOR LOCAL ELECTRICAL
INSPECTOR'S
USE.
READ AND
SAVE THESE
INSTRUCTIONS
FOR FUTURE
REFERENCE.
If the information
in this manual
is not followed
exactly,
a fire or explosion
may
result causing property
damage,
personal
injury or death.
FOR YOUR SAFETY:
--
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
m
WHATTO
DO IFYOU SMELLGAS:
•
Do not try to light any appliance.
•
Do not touch any electrical switch; do not use any phone in your building.
•
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
•
If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed
by a qualified installer, service agency or the gas supplier.
Do not pinch the power supply cord or the flexible gas
conduit
between
the range and the wall.
Do not seal the range to the side cabinets.
**NOTE:
30" (76.2 cm) minimum
clearance between the
cooktop
and the bottom
of the cabinet when the bottom
of wood or metal cabinet is protected
by not less than ¼"
(0.64 cm) flame retardant
millboard
covered with not less
than No. 28 MSG sheet metal, 0.015"
(0.4 mm) stainless
steel, 0.024" (0.6 mm) aluminum,
or 0.020"
(0.5 mm)
copper.
36" (91.4 cm) minimum
clearance when the cabinet is
unprotected.
• NOTE: Allow at least 19 ¼" (48.9 cm) clearance for door
depth when it is open.
• Door Open
(see note)
ulator
Shave Raised
Edge to Clear
30" (76.2 cm)
Wide Cooktop
Rim1
Y2" Max.
(3.8 cm Max.
Locate Cabinet
Doors 1 " (2.5
cm) Min.
from Cutout
Opening.
*Note: 29"
(73.7 cm) Wide
Opening for
Overlapping
Cooktop
and
Built-in Look.
If Installing Model With
Optional
Side Panels,
Cutout Area Including
Countertop
Must Be At
Least 30" (76.2 cm) Wide.
30" Min.
(76.2 cm Min.
18" Min.
cm) Min.
Grounded Jonction Box or Wall
Outlet Should Be Located 8"
to 17" (20.3 cm to 43.2 cm)
From Right Cabinet and 2" to
4" (5.1 cm to 10.2 cm) From
Floor.
22 7/8"
13"
3 cm)
24" Min.
(61 cm Min.)
35 3/8" (90 cm) -
30"
26 1/4"
36 3/8" (92 cm)
(76.2 cm)
(66.7 cm)
29"
21 3/4"
36" (91.4 cm) standard
(73.7 cm)
(55.2 cm)
35 3/8" (90 cm) min.
ol
1/8"
(45.7 cm)
FRONT
G R_,.
OF
CABINET
G. Minimum Cutout Depth is increased to 24" (61 cm) with backguard.
NOTE: Wiring diagram for these appliances are enclosed in this booklet.
P/N 318201650
(0201)
Rev. C
English - pages 1-12
EspaSol - p_tginas 13-24
Fran_ais - pages 25-36
Wiring Diagrams - pages 37-40