Ductwork, Wiring Locations - GE ZVC36LSS Installation Instructions Manual

30", 36", 48" custom hood insert
Table of Contents

Advertisement

Wall Installation
Preparation
DUCTWORK,
WIRING LOCATIONS
Determine the exact location of the insert
sleeve. Mark the exact centerline location.
The ceiling structure must be capable of
supporting the weight of the insert sleeve
(appro×imatelg 100 pounds) and ang
inadvertent user contact loads,
l
• Measure from the top of the cooking
16"above pencil
surface to the bottom edge of the insert
line indicating
sleeve. Add insert sleeve installation height, bottomof hood
Mark that location.
Use a level to draw a straight horizontal
pencil line on the wall.
NOTE: House duct should drop to 11-1/2"
above bottom
edge of insert sleeve.
Location of house duct is important
because it must align with vent of
damper plate assemblg.
4" liner height
30" Min.
36" Max,
installation
height
5-1/2" from
rear wall to
centerline
Ceiling ducting:
If ductwork will vent straight up to the ceiling:
Use a level to draw a centerline straight up
to the ceiling.
On the ceiling, measure 5-1/2" from
the back wall to the centerline of an
8-!/2"
hole.
Wall Ducting:
If ductwork will vent to the rear:
® Use a level to draw a centerline straight
up to the ceiling.
Measure at least 16" above the pencil line
that indicates the bottom installation height,
to the centerline of an 8-1/2" die. duct hole.
(Hole meg be elongated for duct elbow.)
36" from
floor to
countertop
I
Side view
36" from
floor to
countertop
I
I
Front view
HOUSE WIRING LOCATION:
The junction box is located inside the top left
side of the hood.
Wiring should enter the back wall at least
15" above the bottom of the insert sleeve,
and within 6" of the left side of the
centerline.