GE Allegro User Manual page 26

Hide thumbs Also See for Allegro:
Table of Contents

Advertisement

To perform a sensor test:
1. Press the down arrow until you see SENSOR TEST displayed.
2. Press #.
The display scrolls though untested zones and beeps to indicate successful sensor
packets.
3. Count the number of beeps and see Table 6 below for the number required.
4. Trip each sensor.
5. The panel displays TEST DONE when all sensors have been tested.
Table 6: Sensor tripping instructions
Sensor
DTIM
Door/Window
Carbon monoxide alarm Unplug the alarm. Plug it back in, wait 10 seconds, then
Glass guard
Motion sensor
Rate-of-rise heat
detector
Shock sensor
Smoke sensor
Panic button
Keychain touchpad
Remote handheld
touchpad
Hardwire loop
If the panel sounds less than the required number of beeps when a zone/sensor is
tripped, this indicates wireless sensor signal strength is below acceptable limits.
Distances from the receiver and/or installation environment are most likely affecting
the sensor's signal strength. Contact your dealer/installer if this occurs.
22
Tripping instructions
Initiate a sensor test.
Open the secured door or window.
press the test/reset button until the unit beeps 8 times.
Tap the glass 3 or 4 in, from the sensor.
Avoid the motion sensor field of view for 5 minutes, and
then enter its view.
Rub you hands together until warm, and then place one
hand on the detector for 30 seconds.
Tap the glass twice (away from the sensor). Wait at
least 30 seconds before testing again.
Press and hold the test button until the system sounds
transmission beeps.
Press and hold the appropriate panic buttons for 3
seconds.
Press and hold the Lock and Unlock buttons
simultaneously for 3 seconds.
Press and hold the two emergency buttons
simultaneously for 3 seconds.
Open the secured door or window.
Number of beeps
7 to 8
7 to 8
7 to 8
7 to 8
7 to 8
7 to 8
7 to 8
7 to 8
7 to 8
7 to 8
7 to 8
1
Allegro Control Panel User Manual

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents