2.5.13 Configure auxiliary inputs

The way the signals on the auxiliary inputs (Aux-.L and Aux.-R) are handled can be set in the Aux. Input Mode menu (4H).
When the option 'Stereo' is chosen, the signals on both Aux. inputs are distributed as a stereo signal to all channels. This setting
can for instance be used to transmit a music signal during breaks in a conference. Note that the Transmission mode must be set
to 'Aux to All' (menu item 4A) to actually transmit this stereo signal.
The 'Stereo to Mono' and 'Mono+ Emergency' options can be selected when the transmitter is used in combination with an
interpretation system. The Aux. input(s) will be distributed to the Symmetrical Audio Input and Interpreters Module. In this
configuration the 'floor' signal should be connected to the Aux. inputs.
Menu Items
Option
4H Aux. Input
Type:
*
- Stereo
- Stereo to Mono
- Mono + Emergency

2.5.14 Set sensitivity of the inputs

The sensitivity of the audio and Aux. inputs can be set in the Input Sensitivity menus (4I, 4J, 4K) . The sensitivity can be set the
same for all audio inputs (menu item 4K) or for each audio input separately.
Menu Items
Options
4I Sens.Aux.L
4J Sens.Aux.R
4K Sens.Inputs
Mode:
- All
- Per Input ...
Per Input Sensitivity settings:
Menu Items
Options
4K Sens.Input nn
Input nr.:
00...31
The sensitivity screens also display a level meter for a visual indication of the actual signal strength: ▄ = low level, █ = high
level, ▲ = overflow.

2.5.15 Choose transmitter name

The transmitter can be assigned a user-defined name. This name is used in the Transmitter Status screen. The name can be
edited in the Unit Name menu (4L).
Menu Items
Options
4L Unit Name
Name:
- Free text
Description
The Aux. inputs will be distributed in stereo to all channels when the
transmission mode (menu item 1) is set to 'Aux to All'.
The Aux-L and Aux-R inputs are combined into a mono signal and
distributed to the Symmetrical Audio Input and Interpreters Module
(when present).
The Aux-L input is distributed to the Symmetrical Audio Input and
Interpreters Module (when present). The Aux-R input is distributed as
emergency signal to all channels when the emergency switch is closed.
Value
Description
Level:
+6 ... +18 dBV
Set the required sensitivity for the left auxiliary input.
Level:
+6 ... +18 dBV
Set the required sensitivity for the right auxiliary input.
Level:
-6 ... +6 dBV
Set the sensitivity of all audio inputs to a user defined level.
Select this option to go to the 'Per Input Sensitivity Settings'
menu.
Value
Description
Level:
-6...+6 dBV
Select which input to set and select the required sensitivity.
Description
Assign a user defined name to the transmitter (max. 16 characters).
The default name is 'Transmitter'.
BOSCH Security Systems | February 2003