Diagnostic Status:
Internal Data
Device Failure
Power Cord
Indicted
Similar information will be displayed for all other power supplies.
Collecting power status information for components at the compute enclosure
Use the show xfm status all, show blade status all, and show interconnect
status all commands to gather information on compute enclosure component power:
NOTE:
Similar information should be displayed for XFMs 2 through 4.
sd-oa1> show xfm status all
Bay 4 XFM Status:
Health: OK
Power: On
Unit Identification LED: Off
Diagnostic Status:
Internal Data
Management Processor OK
Thermal Warning
Thermal Danger
Power
Firmware Mismatch
Indicted
Link 1: OK
Link 2: OK
Link 3: OK
Link 4: OK
Link 5: OK
Link 6: OK
Link 7: OK
Link 8: OK
sd-oa1> show blade status all
Blade #1 Status:
Power: On
Current Wattage used: 1325 Watts
Health: OK
Unit Identification LED: Off
Diagnostic Status:
Internal Data
Management Processor OK
Thermal Warning
Thermal Danger
I/O Configuration
Power
Cooling
Device Failure
Device Degraded
Device Info
Firmware Mismatch
PDHC
Indicted
sd-oa1> show interconnect status all
Interconnect Module #1 Status:
Status: OK
Thermal: OK
CPU Fault: OK
Health LED: OK
OK
OK
OK
OK
OK
OK
OK
OK <<<<
OK
OK
OK
OK
OK
OK
OK <<<
OK
OK
OK
OK
OK
OK
OK
Methodology