Download Print this page

HP StoreEasy 1000 Specification page 45

Hp storeeasy 1000 storage
Hide thumbs Also See for StoreEasy 1000:

Advertisement

QuickSpecs
Technical Specifications
BTU Rating
Power Supply Output
(per power supply)
System Inlet Temperature Operating
DA - 14434 North America — Version 9 — October 4, 2013
Rated Input Frequency
Rated Input Power
Maximum
Rated Steady-State Power For 1200 W Power Supply:
Maximum Peak Power
Non-operating
HP StoreEasy 1000 Storage
50 to 60 Hz
For 1200 W Power Supply:
930 W (at 100 VAC),
1348 W (at 200 VAC)
For 750 W Power Supply:
857 W (at 100 VAC),
824 W (at 200 VAC)
For 460 W Power Supply:
526 W (at 100 VAC),
505 W (at 200 VAC)
For 1200 W Power Supply:
3530 BTU/hr (at 100 VAC),
4600 BTU/hr (at 200 VAC)
For 750 W Power Supply:
2925 BTU/hr (at 100 VAC),
2812 BTU/hr (at 200 VAC)
For 460 W Power Supply:
1794 BTU/hr (at 100 VAC),
1725 BTU/hr (at 200 VAC)
800 W (at 100 VAC),
900 W (at 120 VAC),
1200 W (at 200 to 240 VAC)
For 750 W Power Supply:
750 W (at 100 to 120 VAC),
750 W (at 200 to 240 VAC)
For 460 W Power Supply:
460 W (at 100 to 120 VAC),
460 W (at 200 to 240 VAC)
For 1200 W Power Supply:
800 W (at 100 VAC),
900 W (at 120 VAC),
1200 W (at 200 to 240 VAC)
For 750 W Power Supply:
750 W (at 100 to 120 VAC),
750 W (at 200 to 240 VAC)
For 460 W Power Supply:
460 W (at 100 to 120 VAC),
460 W (at 200 to 240 VAC)
° to 35°C (50° to 95°F) at sea level with an altitude
derating of 1.0°C per every 304.8 m (1.8°F per
every 1000 ft) above sea level to a maximum of
3048 m (10,000 ft), no direct sustained sunlight.
Maximum rate of change is 10°C/hr (18°F/hr). The
upper limit may be limited by the type and
number of options installed.
System performance may be reduced if operating
with a fan fault or above 30°C (86°F).
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).