Access Control Interface Module
D# Enter Request?
Default:
Selections:
This program item determines if Request to Enter [RTE] events are sent to the panel for
processing memory, printing, and remote reporting.
Yes A DOOR REQUEST TO ENTER event from this door controller is sent to the panel for
processing.
No A DOOR REQUEST TO ENTER event from this door controller is not sent to the panel for
processing.
NOTICE!
RTE events require D# Access Granted to be programmed [YES].
D# Exit Request?
Default:
Selections:
This program item determines if Request to Exit [REX] events are sent to the panel for
processing memory, printing, and remote reporting.
Yes DOOR REQUEST TO EXIT event from this door controller is sent to the panel for
processing.
No A DOOR REQUEST TO EXIT event from this door controller is not sent to the panel for
processing.
NOTICE!
REX events require D# Access Granted to be programmed [YES].
Bosch Security Systems, Inc.
No
Yes or No
No
Yes or No
Program Entry Guide
Event Profile | en
13
F.01U.201.526 | 02 | 2011.10