Dell PowerVault DL4000 Owner's Manual page 95

Dell powervault dl4000 systems owner's manual
Hide thumbs Also See for PowerVault DL4000:
Table of Contents

Advertisement

Error Code
Message Information
Details
Action
PSU1201
Message
Details
Action
PSU1204
Message
Details
Action
PWR1004
Message
Details
Action
PWR1005
Message
Details
Action
PWR1006
Message
Details
Action
RFM1008
Message
Power supplies should be of the same input type and power rating.
Install matched power supplies and review this manual for proper
configuration.
Power supply redundancy is lost.
The power supply tries to operate in a degraded state. System
Performance and power redundancy may be degraded or lost.
Check input power. Reinstall the power supply. If the issue persists,
see
Getting
Help.
The power supplies are not redundant. Insufficient resources to
maintain normal operations.
The current power operational mode is non-redundant because of a
power supply exception, a power supply inventory change, or a
system power inventory change.
Check the event log for power supply failures. Review system
configuration and power consumption.
The system performance degraded because power capacity has
changed.
The system may power down or operate in a performance degraded
state.
Check the event log for power supply failures. Review system
configuration and power consumption and upgrade or install power
supplies accordingly.
The system performance degraded because the user-defined power
capacity has changed.
The user-defined power settings have affected system operation.
If unintended, review system configuration changes and power
policy.
The system halted because system power exceeds capacity.
The system halted because system power exceeds capacity.
Review system configuration, upgrade power supplies or reduce
system power consumption.
Failure detected on Removable Flash Media <
name >.
95