Troubleshooting

If a problem occurs, you may find a cause of the problem by performing the simple inspection.
Before you call repair service personnel, inspect the flowmeter using the flowcharts shown below.

13.2.1 Flow rate is not indicated

Is the rated power supplied for
each device?
Are cables installed correctly?
Isn't the fuse blown?
Is the velocity range set
correctly?
Does the flow direction agree
with the arrow mark on the
detector?
Contact your nearest Toshiba
representative.
START
YES
YES
NO
YES
YES
- 159 -
NO
Use the rated power supply for each
device.
NO
Install the cables correctly according to
5. "Wiring."
YES
Replace the fuse with a new one.
NO
Set the velocity range correctly
according to 8. "Parameter Settings."
Install the detector correctly according to
NO
4. "Installation." In addition, set the
direction of flow correctly according to 8.
"Parameter Settings."