Download Print this page

Frigidaire 2020213A0362 Installation Instructions Manual

Frigidaire slider casement air conditioners installation instructions

Advertisement

Quick Links

Advertisement

loading

Summary of Contents for Frigidaire 2020213A0362

  • Page 2: Electrical Connection

    Electrical ground is required on this appliance. Recommended grounding method: For your personal safety, this appliance must be grounded. This air conditioner includes a power supply cord with a 3-prong grounding plug. To minimize possible electrical shock hazard: -cord must be plugged into a mating 3-prong...
  • Page 3 Make sure you have all the necessary parts. Installation kit contents: Platform (1) Support brace (1) Adjustment bolt (1) Hex flange nut - 1/4" (1) Track seal (1) Side channel seal (1) Foam seal strip/Sash seal Safety bracket (1) 9-11. Screw - #10 x 2-1/2" flat-head (2), OR Screw - #10 x 1-3/4"...
  • Page 4 CAUTION Property Damage Hazard-Failure to adhere to the following precaution could result in damage to window or air conditioner. Be sure wood stool or window track is securely attached to the building construction. Use longer screws in sub-framing if necessary.
  • Page 5 4. Peel off protective backing from track seal. Apply seal to room side of window track. Center of seal strip should coincide with the line marked in Step 2. The two screw holes drilled in Step 3 should be directly above seal strip in the inner track.
  • Page 6 10. Clamp plastic window panel between a board and a work table, and cut along cutting line with a fine tooth saw. Remove any burrs with a file. 11. Fasten side channels to the sides of the AC using 3 screws (Item 17) per channel. Start with first screw at top of channel.
  • Page 7 Use a #8-32x3/4-inch self-threading screw. NOTE: The bracket prevents movement of the air conditioner (either in or out) after completing the installation. 18. Stuff the foam seal strip/sash seal between the vertical sash and the window glass, as shown right.
  • Page 8 Installing the Unit in a Casement Window NOTE: Open the window the maximum amount to allow for clearance of the cabinet. The crank handle should be removed to allow the platform to be fastened to the jamb. If the window cannot open far enough (more than 15-1/2 inches) for the cabinet to clear the window, remove the window entirely by drilling out the rivets.
  • Page 9 5. Adjust the platform assembly so that the rear of the air conditioner will be 3/16-inch lower than the front. This ensures proper water drainage from the air conditioner. NOTE: A projection below the base of the air conditioner will require the rear of the platform to be 7/16-inch lower than the front to create the 3/16-inch slant from front to rear.
  • Page 10 4. Then release the electrical coupler plug. NOTE: DO NOT push or pull air direction louvers. 13. Place the air conditioner in the window opening as shown to the right. It should sit on the platform assembly so that the window panel frame, and the cabinet side channels are against the top and side window jambs.

This manual is also suitable for: