System Error Codes

System Programming Error Codes

System Programming Error Codes
Program
Code
100
102
103
2-2
Sub-
FB
parameter
FB00
33
FB01
33
FB01
33
FB01
33
FB01
49
FB01
49
FB01
49
FB01
49
FB01
49
FB01
49
FB01
50
FB02
50
FB03
50
FB04
50
FB01
54
FB01
33
FB02
33
FB02
49
FB02
50
FB00
51
FB00
52
-
-
Error Descriptions
The entered Cabinet/Slot value is out of range.
The entered PCB Type is out of range.
In CTX100, the Card Type Code other than ASTU (STU) was
assigned into S109.
In CTX670, the equipment entered is S109 or S110.
In CTX100, the equipment entered is S110.
Deleting a Card (000) ñ Programmed station and/or trunk data
must be deleted before a card can be deleted.
Changing Card Type Code ñ Card Type cannot be changed.
Delete the existing Card Type before entering a new Card
Type.
The designated BIOU is already in use.
IOU card cannot be deleted because the Control Relay is
assigned to that card.
The PCB cannot be assigned to the designated equipment
position.
ì004î is not assigned as Card Type Code.
One of the required parameters (PCM Highway, BDKU Type
or TEI Assignment) has not been assigned.
The PCM highway value entered is not applicable for the
desired PCB assignment. PCB parameters are required for
PDKU or BDKU, RDTU, RDSU, RPTU.
The Channel Type value entered is not applicable for the
desired PCB assignment. PCB parameters are required for
PDKU or BDKU, RDTU, RDSU, RPTU.
The TEI Type value entered is not applicable for the desired
PCB assignment. PCB parameters are required for PDKU or
BDKU, RDTU, RDSU, RPTU.
The number of MF2U cards exceeds the system limit.
The entered Feature Code is out of range.
The OLG entered is out of range.
An invalid OLG number was entered in OLG Number field
when assigning a Flexible Numbering Feature code of 551.
ì0î is not a valid OLG Number.
Flexible Numbering Plan values cannot be repeated. The
value entered cannot be registered (e.g., If 1234 is registered,
123 cannot be registered).
The value entered conflicts with an existing extension and
cannot be registered.
See
ìCommon Error Code Tableî