1−12
The following table shows which models need derating.
1-ph 200V class
WJ200-001S
WJ200-002S
WJ200-004S
WJ200-007S
WJ200-015S
WJ200-022S
:need derating
-:need no derating
Use the following derating curves to help determine the optimal carrier frequency
setting for your inverter and find the output current derating. Be sure to use the
proper curve for your particular WJ200 inverter model number.
Legend for Graphs:
Derating curves:
Models need no derating
100%
80%
60%
% of rated
output current
40%
20%
Need
3-ph 200V class
derating
WJ200-001L
WJ200-002L
WJ200-004L
WJ200-007L
WJ200-015L
WJ200-022L
WJ200-037L
WJ200-055L
WJ200-075L
WJ200-110L
WJ200-150L
Ambient temperature 40℃ max., individual mounting
Ambient temperature 50℃ max., individual mounting
Ambient temperature 40℃ max., side-by-side mounting
HD
0
2
4
6
8 10 12
Carrier frequency
Need
3-ph 400V class
derating
WJ200-004H
WJ200-007H
WJ200-015H
WJ200-022H
WJ200-030H
WJ200-040H
WJ200-055H
WJ200-075H
WJ200-110H
WJ200-150H
100%
80%
60%
40%
20%
14
16kH
0
2
Carrier frequency
Need
derating
ND
4
6
8 10 12
14kH