Download Print this page

Dell PowerEdge R900 Update

Information update
Hide thumbs Also See for PowerEdge R900:

Advertisement

Information Update
Added Support for 8-GB Memory Modules
Your Dell™ PowerEdge™ R900 system now supports the following 8-GB memory
configurations:
32 GB — 4 x 8-GB quad-rank memory modules
64 GB — 8 x 8-GB quad-rank memory modules
NOTE:
63.75 GB during POST.
128 GB — 16 x 8-GB quad-rank memory modules
256 GB — 32 x 8-GB quad-rank memory modules
NOTE:
Prior to upgrading your system, verify that the latest system BIOS version is on
your system. Loading the latest BIOS version from support.dell.com will ensure that
your system is fully supported.
NOTE:
Some operating systems cannot support more than 4 GB of physical memory.
For more information on memory support requirements and restrictions, refer to the
operating system documentation that ships with your system.
BMC and DRAC5 Firmware Version Requirements
When upgrading either the BMC or the DRAC5, you must update the firmware
for both components to ensure full functionality and compatibility.
For example, the power reduction feature of the DRAC5 version 1.40 firmware
works only when BMC 2.27 or higher is also installed. If the BMC and DRAC
firmware are incompatible—BMC 2.27 installed with DRAC5 version 1.33 or
BMC 1.79 installed with DRAC5 version 1.40—the power reduction feature may
not function correctly.
September 2008
If 64 GB of memory is installed, the system will only recognize and display

Advertisement

loading

Summary of Contents for Dell PowerEdge R900

  • Page 1 256 GB — 32 x 8-GB quad-rank memory modules NOTE: Prior to upgrading your system, verify that the latest system BIOS version is on your system. Loading the latest BIOS version from support.dell.com will ensure that your system is fully supported. NOTE: Some operating systems cannot support more than 4 GB of physical memory.
  • Page 2 Back Cooling Fans Systems manufactured after September 2008 no longer include the four back cooling fans installed in earlier systems. Therefore, BMC version 2.27 does not recognize the presence of back fans. The back fans will still run in older systems; however, from a system perspective, the fans do not exist and are not monitored.
  • Page 3 Table 1. LCD Status Messages (continued) Code Test Causes Corrective Actions The BIOS has determined See "Getting Help" in your E1716 Chipset that there is a problem Hardware Owner’s Manual. with the chipset, but is unable to determine its origin. CPU is faulty.
  • Page 4 Information in this document is subject to change without notice. © 2007–2008 Dell Inc. All rights reserved. Printed in the U.S.A. Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden. Trademarks used in this text: Dell and the DELL logo are trademarks of Dell Inc.