TOSLINE-S20 Active Star Coupler (ASC25) Instruction Manual
5.
Specifications
The section describes the specifications of the Active Star Coupler.
(1)
General specifications
General specifications of Active Star Coupler are given below.
Item
Voltage
Rating
Fluctuation range
Power
Supply
Power consumption
Retentive power interruption Resuming to normal operation within 10 ms
Insulation rating
Fuse rating
Tempe-
Operating
rature
temperature
Storage
temperature
Humidity
Environ-
ment
Vibration
Atmosphere
Dust
Ground
External dimensions
Weight
Cooling
Installation position
TOSLINE S20
Specification
100/110 V AC, 50/60 Hz
200/220 V AC, 50/60 Hz
85 to 132 V AC, 47 to 66 Hz
170 to 250 V AC, 47 to 66 Hz
about 10 VA
1500 V AC for 1 minute
250V-3A
0 to 55 C (unit ambient temperature)
20 to 75 C (unit ambient temperature)
20 to 90% RH, no condensation
Conforming to JIS C0911
Power OFF, Frequency 16.7 Hz, Displacement 3 mm
Free from corrosive gas
Not more than 1 mg/m
Grounding resistance 100Ħ or less
390 (W)
200 (D)
70 (H) mm
approximately 3.0 kg
Natural air cooling
Horizontal (unacceptable of upside down or vertical
position)
Table 5.1
11
3
6F3B0360