Frigidaire PL30DD Instructions Manual page 9

Downdraft blower system
Hide thumbs Also See for PL30DD:
Table of Contents

Advertisement

DOWNDRAFT TOP COVER ASSEMBLY
INSTALLATION
TOP
COVER
ACTIVATING
SWITCH
CHIMNEY
1. Press activating switch to raise chimney. NOTE: If electri-
cal power supply is not connected, lift chimney manually
and cock it slightly to keep it in position. Remove four (4)
screws and remove existing top cover.
2. Slide legs on top cover into ends of chimney as shown.
Make sure switch membrane is above activating switch.
Fasten with four (4) screws provided.
SWITCH
MEMBRANE
LEG
2 MOUNTING
SCREWS
EACH SIDE
ADJUSTMENT
The downdraft is factory-adjusted for proper operation. How-
ever, shipping and handling may affect the position of the
activating switch.
To adjust position of activating switch:
WARNING: To avoid possible electri-
cal shock, personal injury or death -
Disconnect electrical power.
1. If downdraft is plugged into electrical outlet, unplug it.
2. Lift air vent straight up and cock it slightly so it remains in the
UP position.
ADJUSTING
SCREW
SWITCH
BRACKET
ADJUSTING
SCREW
3. Remove switch cover from right end of air vent.
4. Loosen the 2 screws holding the switch bracket in place.
Position switch bracket so that activating switch just comes
in contact with underside of switch membrane. Tighten
screws.
5. Replace switch cover, gently lower air vent into chimney,
and plug in power cord. Re-connect electrical power and
check operation.
SWITCH
MEMBRANE
ACTIVATING
SWITCH
SWITCH
COVER

Advertisement