Canon VB150 User Manual page 39

Network camera server guide to creating web pages for video distribution
Hide thumbs Also See for VB150:
Table of Contents

Advertisement

Remote Firmware Upgrade-related Log Messages
●I001 Remote firmware upgrade write error (err)
cannot reboot as the firmware is broken
Message
Explanation
Reboot cannot take place because there is an error in the firmware that was written
onto read-only memory during the firmware remote upgrade. This error is not a transfer
error and has not occurred as a result of a break in transfer. This type of error occurs
only when firmware is erased from the ROM or when firmware is written onto the ROM.
Response
Contact your local Canon service representative. There is a possibility that the flash
ROM chip has been damaged.
●I002 Application program is stopped because of the remote firmware upgrade (info)
Message
application is halted for updating the firmware
Explanation
The application program has been stopped so that the firmware can be installed
remotely. All operations for WebView, picture recording and external device output
control that are underway will be discontinued, and new commands will not be
accepted until a reboot has been carried out.
●I003 Remote firmware upgrade completed (info)
firmware is updated
Message
The remote firmware upgrade process has been completed.
Explanation
●I004 Reboot due to remote firmware upgrade timeout (warnning)
reboot as the firmware update time is out
Message
Explanation
The VB150 restarted due to firmware remote installer timeout. This happens when
communication with the installer has been cut for 5 minutes due to network error etc.
Response
Check to be sure that the camera server has been restarted. (Refer to the version
and revision numbers that are displayed at the top of the settings title page and
check that the numbers are that of previous version firmware).