Asus AP1700 User Manual

Intel xeon tower/5u rackmount server with 533mhz fsb support

Advertisement

Quick Links

®
AP1700
®
Intel
Xeon Tower/5U Rackmount Server
with 533MHz FSB support
User's Manual

Advertisement

Table of Contents
loading

Summary of Contents for Asus AP1700

  • Page 1 ® AP1700 ® Intel Xeon Tower/5U Rackmount Server with 533MHz FSB support User’s Manual...
  • Page 2: Disclaimer/Copyrights

    ASUS; or (2) the serial number of the product is defaced or missing. Products and corporate names appearing in this manual may or may not be registered trademarks or copyrights of their respective companies, and are used only for identification or explanation and to the owners’...
  • Page 3: Asus Contact Information

    Technical Support Support Fax: +1-510-608-4555 General Support: +1-502-933-8713 Web Site: www.asus.com Support Email: tsd@asus.com ASUS COMPUTER GmbH (Germany & Austria) Address: Harkortstr. 25, 40880 Ratingen, BRD, Germany General Fax: +49-2102-442066 General Email: sales@asuscom.de (for marketing requests only) Technical Support Support Hotline:...
  • Page 4: Fcc/Cdc Statements

    This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications. This class B digital apparatus complies with Canadian ICES-003. ASUS AP1700...
  • Page 5: Table Of Contents

    Contents Disclaimer/Copyrights ............... ii ASUS Contact Information ............... iii FCC/CDC Statements................ iv Safety Precautions ................vii Electrical Safety ................vii Operation Safety ................vii Introduction About this guide ............I-1 Audience ................... I-2 Contents .................... I-2 Conventions ..................I-3 References ..................I-3 System Package Contents ..............
  • Page 6 2.11 Chassis Fan ................. 2-24 2.12 Connecting Cables .............. 2-25 2.13 SCSI Backplane ..............2-26 Appendix A: Optional chassis roller-wheel Chassis Roller-wheel Installation ..........A-2 Appendix B: Power Modules Redundant Power Modules ............A-4 Appendix C: Troubleshooting Troubleshooting ................A-9 ASUS AP1700...
  • Page 7: Safety Precautions

    Safety Precautions Electrical Safety IMPORTANT • Before installing or removing signal cables, ensure that the power cables for the system unit and all attached devices are unplugged. • To prevent electrical shock hazard, disconnect the power cable from the electrical outlet before relocating the system. •...
  • Page 8 ASUS AP1700...
  • Page 9: Introduction

    Introduction “About This Guide” introduces the contents of this document. This part includes the target audience, chapter description, and conventions used. It also lists other sources of information that are not contained in this manual. User’s Manual...
  • Page 10: Audience

    This appendix lists the common problems that you may encounter while using the AP1700 server. It lists the possible causes of the problems and offers solutions. You may refer to this part and try to solve simple problems before calling customer support. ASUS AP1700...
  • Page 11: Conventions

    2. ASUS Websites The ASUS websites worldwide provide updated information on ASUS hardware and softare products. The ASUS websites are listed in the ASUS Contact Information on page v. 3. Optional Documentation Your product package may include optional documentation such as a CD-ROM manual, warranty flyers, and others that may have been added by your dealer.
  • Page 12: System Package Contents

    Special heatsink with fan assembly (2 sets) Hot swap SCSI hard disk drive tray (6 units) AC power cord (2 pieces) Support CD that includes drivers, utilities, ASUS System Monitoring Agent (ASMA) with the ASUS Server Web-based Management (ASWM) Trend Micro Server Protect anti-virus software full user version CD...
  • Page 13 Chapter 1 This chapter describes the general features of the AP1700 system server. It includes sections on front panel, rear panel and internal specifications. User’s Manual...
  • Page 14: System Features

    1.1 System Features The ASUS AP1700 server is a stylish server system featuring the ASUS PR-DLS533 motherboard. The server supports the Intel Xeon ® ™ processor in a 604-pin socket, and includes the latest I/O, LAN, and video technologies through the chipsets embedded on the motherboard.
  • Page 15: Front Panel Features

    1.2 Front Panel Features The front panel allows easy access to the hard disk drives. The power and reset buttons, LED indicators, optical drive, floppy drive and two USB connectors are also located on the front panel. For future installation of 5.25 devices, there are two drive bays available. The front panel of the server is protected by a door and lock for added security.
  • Page 16: Rear Panel Features

    Parallel port VGA port Chassis Lock Dual Gigabit LAN ports 6 Full-Length PCI Slots High Density 68-pin SCSI Connector You may secure the chassis lock with an additional padlock or other security device for added server system security. ASUS AP1700...
  • Page 17: Internal Features

    1.4 Internal Features The standard components inside the server include the motherboard, power supply, floppy and CD-ROM drives, and cables. The picture below shows the standard components of the server. 6. 5 x 64 bit 3V PCI-X slots 1. Redundant power supply cage 7.
  • Page 18: Led Table

    Suspend Mode Blinking No activity HDD Access Read/Write data in HDD Blinking Normal/No incoming event Message ASMS indicate Blinking monitor event *SCSI Access Fault - Tolerant Enclosure Only RAID cards with SAF-TE feature is enabled with HDD rebuilding function. ASUS AP1700...
  • Page 19 Chapter 2 This chapter lists the hardware setup procedures that you have to perform when installing system components. User’s Manual...
  • Page 20: Removing And Installing Chassis Cover

    2.1.1 Removing the chassis cover 1. Loosen the two thumb screws that secure the side cover. 2. Slide the chassis cover for about half an inch toward the rear until it is disengaged from the chassis. Half-inch gap ASUS AP1700...
  • Page 21: Installing The Cover

    2.1.2 Installing the cover 1. Match and insert the hooks of the cover to the elongated holes on the side of the chassis. All the six hook (three each on the top and bottom) of the cover must properly fit the designated holes. 2.
  • Page 22: Motherboard Placement

    Place this side towards the rear of the chassis Motherboard Screws Place thirteen (13) screws into the holes indicated by circles to secure the motherboard to the chassis.Do not overtighten the screws! Doing so may damage the motherboard. ASUS AP1700...
  • Page 23: Central Processing Unit

    Installing the Central Processing Unit (CPU) In the event of conflict between this instruction and other references cited herein, instructions in this system manual takes precedence. 2.3.1 Overview The motherboard comes with dual surface mount 604-pin Zero Insertion Force (ZIF) sockets. The sockets are designed for the Intel Xeon Processor in the 604-pin package with 512KB L2 cache.
  • Page 24: Installing The Cpu

    CPU! 4. When the CPU is in place, press it firmly on the socket while you push down the socket lever to secure the CPU. The lever clicks on the side tab to indicate that it is locked. ASUS AP1700...
  • Page 25 2.3.3 Installing the CPU heatsink with fan assembly ® The Intel Xeon™ processors require especially designed heatsink and fan assembly to ensure optimum thermal condition and performance. Make sure that the heatsink with fan assembly is properly installed on the motherboard.
  • Page 26 5. If you wish to install two CPUs, repeat the same steps for CPU socket 2. 6. Use CPUFAN2 connector for the second CPU heatsink and fan assembly cable. ASUS AP1700...
  • Page 27: System Memory

    System memory 2.4.1 Overview The motherboard comes with six Double Data Rate (DDR) Dual Inline Memory Module (DIMM) sockets. These sockets support up to 12GB system memory using 184-pin registered PC2100/1600 DIMMs with Serial Presence Detect (SPD) and Error Check and Correction (ECC). 104 Pins 80 Pins DDRA1...
  • Page 28: Memory Configurations

    SDRAM 128MB, 256MB, 512MB, 1GB, 2GB DDRC2 SDRAM 128MB, 256MB, 512MB, 1GB, 2GB Total System Memory (Max. 12GB) = The system chipset only supports PC2100/1600 registered ECC DIMMs. Make sure to use only the specified DIMM types for stable system operation. 2-10 ASUS AP1700...
  • Page 29: Installing A Dimm

    2.4.3 Installing a DIMM Make sure to unplug the power supply before adding or removing DIMMs or other system components. Failure to do so may cause severe damage to both the motherboard and the components. Follow these steps to install a DIMM. 1.
  • Page 30: Fixed Device Bays

    An IDE CD-ROM drive is installed on the uppermost bay and two free bays are available for installation of additional storage devices like optical disc drives or tape drives. Front door bezel Screwless fixed device bay locks 2-12 ASUS AP1700...
  • Page 31 2.5.2 Installing a 5.25 device Make sure to unplug the AC power supply before adding or removing any 5.25 fixed device or other system components. Failure to do so may cause severe damage to both the motherboard and the system components.
  • Page 32 45º counter-clockwise until it clicks on the reference point near the “unlocked icon”. Unlock Reference points icon Locked icon Knob 4. When released, pull- out the lock and set it aside. 2-14 ASUS AP1700...
  • Page 33 5. Carefully insert device (such as CD/DVD-ROM drive) into the selected bay. 6. Secure the drive to the bay using the screwless drive bay lock that you removed earlier. 6.a Match the two pegs on the lock to the holes on the drive bay. 6.b Turn the knob 45º...
  • Page 34 “2.5.2 Installing a 5.25 device” on page 2-13. 2. Remove the two screws that secure the right side chassis cover. 3. Pull out and detach the right side chassis cover. Set aside. 4. Locate the floppy disk drive cable and power connectors. 2-16 ASUS AP1700...
  • Page 35 Carefully detach the floppy disk drive cable. Carefully detach the floppy disk drive power cable. 5. Pull out the floppy disk drive tray while squeezing the two tabs together. Floppy disk drive tray User’s Manual 2-17...
  • Page 36: Hard Disk Drives

    To release the drive bay, follow these steps. 1. Lift the spring lock upwards, then pull the tray lever outwards. 2. When the tray lever is pulled down, the tray will eject slightly. Pull the tray outwards on the tray lever. 2-18 ASUS AP1700...
  • Page 37 2.6.1 Placing an SCA SCSI Hard Drive to tray 1. Place an SCA SCSI hard drive into drive tray and secure the drive using the bundled four (4) screws. 2. After the drive is secured to the tray, carefully insert the drive into the bay.
  • Page 38: Screwless Expansion Card Slot

    Take caution in handling the metal plate, the sharp edges may cause body injury. 3. To lock, make sure that all expansion cards are properly inserted in the slots, then pull the spring lock lever to fasten the expansion cards in place. 2-20 ASUS AP1700...
  • Page 39: Long Card Support Guide

    2.8 Long Card Support Guide The long card support guide secures that long expansion cards are positioned firmly in place. Make sure the handle of the expansion card is locked in the expansion card guide. To install a long expansion card, follow these steps. 1.
  • Page 40: Raid Card

    133MHz, two (2) PCI cards installed will get a maximum speed of 100MHz and three (3) PCI cards will get maximum speed of 66MHz. • PCI-X5 slot supports LSI MegaRAID U320-0 Zero Channel RAID 2-22 ASUS AP1700...
  • Page 41: Hard Drive Blower

    2.10 Hard Drive Blower The hard drive module is cooled by a blower mounted under the hot swap ® bays.The drive blower status can be monitored through the ASUS Server Management Software (ASMS) for remote management convenience. 2.10.1 Removing the hard drive blower To remove the hard drive blower, follow these steps.
  • Page 42: Chassis Fan

    1. Remove the 12-cm chassis fan 3-pin power cable (SYSFAN3) from the motherboard. chassis fan pin-locks 2. Release all four (4) pin-locks by squeezing the pin tail and pushing the pin to the rear panel. 3. Pull out the 12-cm chassis fan. 2-24 ASUS AP1700...
  • Page 43: Connecting Cables

    2.12 Connecting Cables Most of the cables in the server are already pre-connected to their respective connectors. The following illustrates the corresponding components that are connected to these connectors. 7.SMBUS Panel to backplane 1. Chassis fan (SYSFAN3) 8. Floppy Disk Drive 2.
  • Page 44: Scsi Backplane

    HDD blower power cable connect to FAN1 Power connectors SCSI cable HDD Access LED Power supply output connector SMBus to MB connector MB SMBus connector 2-26 ASUS AP1700...
  • Page 45 2.13.2 SCSI Backplane frontside and backside The SCSI backplane assembly of this server is comprised of one SCSI board (BP6LS-AS35) with 68-pin SCSI connector, two 12V power inputs, two fan connectors (FAN1, FAN2) and three jumper connectors (J1, J2, J3). This configuration allows SCA SCSI hard disk drives to be docked into the server.
  • Page 46 2-28 ASUS AP1700...
  • Page 47 Appendix A This appendix contains the installation procedure for the optional chassis roller-wheel units for the AP1700 server system. User’s Manual...
  • Page 48: Chassis Roller-Wheel Installation

    2. Affix each plastic rubber wheel unit by mounting its screws on designated slots at the bottom of the chassis. 3. Make sure the screws are tightened accordingly. chassis roller-wheel brake locks All the chassis roller-wheels can be locked individually with its built-in chassis-roller wheel brake locks. ASUS AP1700...
  • Page 49 Appendix B This appendix contains detailed hardware operation and specifications of the AP1700 redundant power modules. User’s Manual...
  • Page 50: Redundant Power Modules

    To remove the redundant power supply module, follow these steps. 1. Remove the screw. 2. Pull on the handle while pressing down the rubber lever. Redundant Power Housing Lever Screw 500W Redundant Power Module ASUS AP1700...
  • Page 51 Redundant Power Module Specifications Output Voltage Regulation Output Voltage Min (V) Nom (V) Max (V) Ripple/Noise +3.33V 3.20 3.33 3.50 50mV 4.75 5.00 5.25 50mV +12V 11.4 12.00 12.60 120mV -12V -10.8 -12.00 -13.20 120mV +5VSB 4.75 5.00 5.25 50mV Output Current Capacity Output Voltage Min (A)
  • Page 52 2. Remove all power cable connections from SCSI backplane, motherboard, floppy and CD-ROM. 3. Remove the six (6) chassis bar screws and release chassis bar. 4. Remove the two (2) right-side chassis cover screws to release right-side cover. ASUS AP1700...
  • Page 53 5. Remove the four (4) power case side screws. 6. Remove the six (6) power case top screws. Make sure the power case is well supported or held when releasing the power case screws. The power case may accidentally detach and cause damage to the other components of the server system.
  • Page 54 ASUS AP1700...
  • Page 55 Appendix C This appendix lists the common problems that you may encounter while using the AP1700 server system. It lists possible causes of the problems and offers solutions. You may refer to this part and try to solve simple problems before calling customer support.
  • Page 56: Troubleshooting

    1. Check the memory modules power-on self tests (POST) after and make sure you installed it was turned on the correct DIMMs the system supports. 2. Make sure that the DIMMs are properly installed on the sockets. A-10 ASUS AP1700...
  • Page 57 Problem Action 1. Check the memory modules The system continuously beeps and make sure you installed after it was turned on the correct DIMMs the system supports. 2. Make sure that the DIMMs are properly installed on the sockets. 3. Check if it has VGA output. 1.
  • Page 58 A-12 ASUS AP1700...

Table of Contents