Boot Device Priority

Slot 1 16-bit ISA or 32-bit PCI
Slot 2 32-bit PCI
Slot 3 32-bit PCI
Slot 4 32-bit PCI
Slot 5 32-bit PCI
Slot 6 32-bit PCI
Slot 7 32-bit PCI
Slot 8 32-bit PCI
Boot order for PCI controllers is determined by slot location. The system searches for a bootable device
in the following order:
1.
IDE CD-ROM drive with a bootable CD-ROM.
2.
Flexible disk drive with a bootable flexible disk.
3.
Embedded SCSI controller or embedded DAC.
4.
PCI boards in slots in the following order: 8, 7, 6, 5, 4, 3, 2, 1.

DIMM Slot LED Blink Codes

= LED on
= LED off
Alternating Blink Code:
LED LED LED LED
0
1
2
3
4
LED Error Codes
Error Condition
Primary VRM Failure
Secondary VRM
Failure
Processor Over-
Temperature
Corrective Action
Check that primary voltage regulator module
(VRM) is correctly seated. If problem persists,
replace VRM.
Check that secondary VRM is correctly
seated. If problem persists, replace VRM.
Check fan for function. Turn off system, wait
20-25 minutes for system to cool, and restart
system.