Specifications - HP D5970A - NetServer - LCII Service & Reference Manual

Hp netserver service handbook, volume 1 - low end
Hide thumbs Also See for D5970A - NetServer - LCII:
Table of Contents

Advertisement

Fig
*
SCSI Slot Filler
*
HP Rail Kit

Specifications

Temperature
Operating
Non-operating
Humidity (noncondensing)
Operating
Non-operating
Altitude
Operating
Non-operating
Weight and Dimensions
Height
Width
Depth
Weight, chassis fully loaded
Weight, chassis empty
Power Requirements
Input voltage range
Frequency
Typical AC input requirements for fully loaded configuration (73% of power supply capability):
Nominal Volts
100
120
200
230
Power supply type
DC output power
Peak AC inrush current
Description
5 to 35 C (40 to 95 F)
–40° to 65° C (-40 to -140 F)
20% to 80% relative humidity
Maximum 95% relative humidity
3,046 m (10,000 ft)
12,200 m (40,000 ft)
13.2 cm (5.19 in)
46.36 cm (18.25 in)
71.76 cm (28.25 in)
37.7 kg (83 lb)
15.9 kg (35 lb)
90-264 VAC
47-63 Hz.
Amps
Watts
5.48
537
4.51
530
2.61
512
2.25
507
Wide input range, power factor corrected
500 Watts DC, continuous, maximum
30 Amps @ 230 VAC
Replacement
Exchange
D5989-63004
D5989-60003
93

Advertisement

Table of Contents
loading

Table of Contents