Dell PowerEdge M420 Administrator's Manual page 68

8/4 gbps fc san module administrator's guide
Hide thumbs Also See for PowerEdge M420:
Table of Contents

Advertisement

B
portCfgShow
FC Fastwrite
Rate Limit
Credit Recovery
Port Auto Disable
F_Port Buffers
Notes
The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may
be in place. Refer to
Admin Domain restrictions"
Operands
This command supports the following operands:
slot
port
Use portCfgshow with one of the following options and optional arguments to display specific
FCIP-related parameters configured for a GbE port:
Examples
To display the configuration settings for a single port on a switch with NPIV mode enabled:
To display the configuration settings for all ports on a switch with NPIV Mode enabled:
54
Displays ON when FC Fastwrite is enabled on the port or (..) or OFF when
disabled. Fastwrite is disabled by default. This value is set by the portCfg
fastwrite command.
Displays ON when ingress rate limit is set on the port or (..) or OFF when the
ingress rate limiting feature is disabled. This value is set by the portCfgQos
--setratelimit command. The default value is OFF.
Displays ON when Credit Recovery is enabled on the port. Displays (..) or OFF
when the feature is disabled. This value is set by the portCfgCreditRecovery
command. The credit recovery feature is enabled by default, but only ports
configured as long distance ports can utilize this feature.
Displays On when the Auto Disable feature is enabled on a port. Displays (..)
or OFF when the feature is disabled. This feature causes ports to become
disabled when they encounter an event that would cause them to reinitialize.
This feature is enabled by the portCfgAutoDisable command. The feature is
disabled by default.
Displays the number of configured internal port (F_Port) buffers. Displays (..)
or OFF if no buffers are configured. The buffer value is set by the
portCfgfPortbuffers command.
"Understanding Virtual Fabric restrictions"
on page 33 for details.
For bladed systems only, specifies the slot number of the port to be
configured, followed by a slash (/).
Specifies the number of the port to be displayed, relative to its slot for bladed
systems.
switch:admin> portcfgshow 8
Area Number:
Speed Level:
Fill Word:
Trunk Port
Locked N_Port
Persistent Disable
NPIV capability
QOS Port
Port Auto Disable:
Rate Limit
F_Port Buffers
Ports of Slot 0
0
-----------------+--+--+--+--+----+--+--+--+----+--+--+--+----+--+--+--
Speed
AN AN AN AN
Fill Word
0
8
AUTO(HW)
0(Idle-Idle)
ON
OFF
OFF
ON
AE
OFF
OFF
OFF
1
2
3
4
5
6
7
AN AN AN AN
0
0
0
0
0
0
0
Dell 8/4Gbps FC SAN Module Administrator's Guide
on page 32 snf
"Understanding
8
9 10 11
12 13 14 15
AN AN AN AN
AN AN AN AN
0
0
0
0
0
0
0
0
53-1001345-01

Advertisement

Table of Contents
loading

Table of Contents