Start Configuration Database Diagnostic - Dell PowerVault MD3620f Command Line Interface Manual

Powervault modular disk storage arrays
Hide thumbs Also See for PowerVault MD3620f:
Table of Contents

Advertisement

Start Configuration Database Diagnostic

This command starts a diagnostic test to validate the configuration database
in the controller firmware.
Syntax
Start storageArray configDbDiagnostic
Parameters
None.
Notes
Upon completion of the diagnostic test, the controller firmware returns one
of these results:
Diagnosis completed without errors. No ZIP file
created.
Diagnosis completed with errors. Refer to the ZIP
file created at:
...\Install_dir\data\FirmwareUpgradeReports\times
tamp_buildNo.zip
If the diagnostic test detects an inconsistency in the configuration database,
the controller firmware performs these actions:
Returns a description of the inconsistency
Saves a ZIP file containing raw binary data
The controller firmware saves the ZIP file to this location:
...\Install_dir\data\FirmwareUpgradeReports\timestamp_buildNo.zip
The binary data can be used to help determine the cause of the problem, or
the file containing the binary data can be sent to a Customer and Technical
Support representative.
To stop the database configuration diagnostic test, use the stop
storageArray configDbDiagnostic command.
Script Commands
293

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powervault md3600f

Table of Contents