HP 4400 Software Manual page 61

Hp enterprise virtual array updating product software guide (xcs 10000000) (667991-001, july 2011)
Hide thumbs Also See for 4400:
Table of Contents

Advertisement

Figure 31 Code Load Disk Drives On Line – Page 2 window
10. Click Next step.
The disk drive firmware upgrade begins. A status page opens, indicating the progress of the
upgrade for each disk drive
(Figure 32 (page
61)).
The disk drives are upgraded sequentially. Depending on the I/O load on the array, it can
take from 30 seconds to 3.5 minutes per drive to upgrade the firmware. The status is updated
at 45-second intervals.
CAUTION:
Do not select an array to manage it during the disk drive upgrade. If you select
an array in the navigation pane to manage it, the disk drive upgrade stops. For example, if
the upgrade was completed on 10 of 27 drives when you selected the array, only those 10
drives have been upgraded. If you start another disk drive upgrade, the status box on the
status window displays NO for the 10 drives that have been upgraded, and the remaining
17 drives are not shown as upgraded. Proceed to upgrade the remaining drives.
Figure 32 Code Load Disk Drives On Line – status window
Step 6. Upgrading the disk drive firmware
61

Advertisement

Table of Contents
loading

This manual is also suitable for:

6400/8400

Table of Contents