Exit Screen - Dell 1955 Hardware Owner's Manual

Dell poweredge 1955 servers: user guide
Hide thumbs Also See for 1955:
Table of Contents

Advertisement

Table 2-7. System Security Screen Options (continued)
Option
Setup Password
Password Status
Power Button
AC Power Recovery
(Last default)

Exit Screen

After you press <Esc> to exit the System Setup program, the Exit screen displays the following options:
Save Changes and Exit
Discard Changes and Exit
Return to Setup
50
Using the System Setup Program
Description
Restricts access to the System Setup program in the same way that
you restrict access to your system using the System Password
feature.
NOTE:
See "Using the System Password" on page 51 for instructions
on assigning a setup password and using or changing an existing
setup password.
Setting the Setup Password option to Enabled prevents the system
password from being changed or disabled at start-up.
To lock the system password, assign a setup password in the Setup
Password option and then change the Password Status option to
Locked. In this state, you cannot change the system password
using the System Password option and the system password cannot
be disabled at start-up by pressing <Ctrl><Enter>.
To unlock the system password, enter the setup password in the
Setup Password field and then change the Password Status option
to Unlocked. In this state, you can disable the system password at
start-up by pressing <Ctrl><Enter> and then change the
password using the System Password option.
Enables or disables the server module's power button.
• If you turn off the server module using the power button and you
are using an ACPI-compliant operating system, the server module
can perform an orderly shutdown before power is turned off.
• If the server module is not running an ACPI-compliant operating
system, power is turned off immediately after the power button is
pressed.
The button is enabled in the System Setup program. When
disabled, the button can only turn on server module power.
Determines how the server module reacts when power is restored.
If the option is set to Last, the server module returns to the last
power state. On turns on the server module after power is restored.
When set to Off, the server module remains off after power is
restored.