Error messages

Message
Memory backup issues
Check Sum Error!
Low Battery!
Low Battery !
Replace Battery !
Low Battery !
Factory Preset ? Replace Battery !
Battery is Exhausted !
Replace Battery !
Communication issues
MIDI port is not selected!
Port busy. Try again.
TX buffer full. Try again.
Work Memory full!
MIDI Framing Error
MIDI Overrun Error
MIDI Parity Error
MIDI RxBuf. Full
MIDI TxBuf. Full
SLOT1 Framing Error
SLOT1 Overrun Error
SLOT1 Parity Error
SLOT1 RxBuf. Full
SLOT1 TxBuf. Full
USB RxBuf. Full
USB TxBuf. Full
Check sum did not match between shutdown and startup.
A memory backup problem has occurred, perhaps because the battery is low.
The backup battery has run low. Replace the battery.
The battery is low. Replace the battery.
The battery is low. Replace the battery.
The battery is dead. Replace the battery.
This will appear if you attempt to execute a bulk dump with the MIDI PORT
unspecified.
Port Busy occurred while executing a MIDI bulk dump.
Try the operation once again.
TX Buffer Full occurred while executing a MIDI bulk dump.
Try the operation once again.
Memory could not be allocated for the MIDI bulk dump.
There was a framing error in the message received at the MIDI port.
Check whether an appropriate device is connected.
There was an overrun error in the message received at the MIDI port.
Check whether an appropriate device is connected.
There was a parity error in the message received at the MIDI port.
Check whether an appropriate device is connected.
The MIDI port reception buffer has overflowed.
Cause: The amount of data being received is too great, or the system has been
loaded for an extended period of time.
The MIDI port transmission buffer has overflowed.
Cause: The amount of data being transmitted is too great, or the system has
been loaded for an extended period of time.
There was a framing error in the message received at the SLOT1 serial port.
Check the serial bridge settings of the MY card.
There was an overrun error in the message received at the SLOT1 serial port.
Check the serial bridge settings of the MY card.
There was a parity error in the message received at the SLOT1 serial port.
Check the serial bridge settings of the MY card.
The SLOT1 serial port reception buffer has overflowed.
Cause: The amount of data being received was too great, or the system has been
loaded for an extended period of time.
The SLOT1 serial port transmission buffer has overflowed.
Cause: The amount of data being transmitted was too great, or the system has
been loaded for an extended period of time.
The USB port reception buffer has overflowed.
Cause: The amount of data being received was too great, or the system has been
loaded for an extended period of time.
The USB port transmission buffer has overflowed.
Cause: The application on the communicating PC terminated abnormally, etc.
Disconnect and reconnect the cable, and restart the application.