ADJUSTMENTS
INPUT LEVEL METER ADJUSTMENT
CONDITONS
a. MAIN
VR
: MIN
-
b. BALANCE
VR_:
CENTER
c. EQ
VR
: CENTER
d. MODE
SW
: STEREO
e. NO
signal
Adjust SVR
902 to become 60mV at
A.
(LED P.C.B)
4-290T73400 TOP VIEW
CLOCK
ADJUSTMENT
(1) Connect the Frequency Counter to TP401 and TP102 on the P.C.Board.
(2) Function SW:
FM mode
Tuning Indication:
87.5 MHz
Adjust CT401 so that the Frequency Counter indicates [2MHz + 100Hz].
Note:
Frequency Counter:. High impedance Input, more than 1 MOHM.