HP-IB INTERFACE/26067B
System Controller
256XA/B
(HP 3000 GIC)
Device A
line Printer
7 loods
1 load
HP-IB Interfoce
intemal
internal
X Installed
Load(s)
2 metre cobl e
o
metre coble
1 Internal Load
lntemcl
internet
Q
Metre Internal Coble
L-.J
LJ
L-.J
~~
8
me
Ires
DEVICE
LOADS
CABLE
SYSTEMGIC
7 Internal
2
Internal
2
Interconnect
DEVICEA
1 Internal
8
Interconnect
HP 25GXA/8
LINE PRINTER
Internal
X
Installed
9
+
X
12 Metres
Loads Total
Coble
Total
Install 3 loads (0 "1 LOAD" and 0 "2 LOAD")
into the 2563A printer I/O driver load sockets.
DRHPIB23
When installing or changing cabling, observe the following recommendations:
Figure 2-3. HP-IB Cable Loading Example
Connect multiple devices to the system in a
linear
(serial/ daisy-chain)
configuration
rather
than
in
a
star
(radial/cluster)
conf igura tion.
The total length of cable (in metres) used,
must be less than
or equal to the total
number of device loads on the HP-IB bus.
If, For example, a system includes an HP3000, an
HP 2563A Line Printer, and some other device
(DEVICE A) as shown in figure 2-3, the loads
are calculated as shown. For the number of loads
to equal the number
of metres of cable (12
metres), 3 loads need to be added since nine are
already available.
Thus, a 1 load and a 2 load
resistor pack can be installed into the I/O driver
load sockets, from the load storage sockets, to
increase the number of total loads to 12.
Connect the device containing the most loads
furthest from the system controller.
The maximum
total
cable length
IS
15
metres and total number of loads
IS
15 for
any HP-IB bus configuration.
The device containing
the most internal
loads should be connected with the longest
cable.