32. Scroll down to highlight ER Log. A log of Error Codes can be viewed here.
33. Press Back to return to the Trace Mode display.
34. By selecting More or Option 9, scroll down to highlight the Reset log. If there are any resets,
you can view them here.
35. Press Back to return to the Trace Mode display.
36. Scroll down to highlight Coin Cell, and then press View to show the Preset Charging Voltage
on line 1 and Current Battery Voltage on line 2.
37. Press Back to return to the Trace Mode display.
6.3

Technician Test Procedures

Technician Tests usually require special equipment to test the functionality of the components in the
unit.
The following tests check the software functionality of the unit:
Codeplug Help
Codeplug Troubleshooting
6.4

Programming the i930 Unit

Use Radio Service Software (RSS) to activate a new software utility or to program specific codeplug
user information.
Refer to Radio Service Software's Help Menu, iDEN Service Bulletins, the Motorola iDEN website,
or contact iDEN Customer Care for information on the setup and use of RSS.
NOTE: iDEN Service Bulletins, Software Utilities, and Updates can be found online at:
http://idenphones.motorola.com/iden/support/
6.5

Connecting the Unit to the RSS Workstation

Some technician tests enter programming information into the unit. To perform these tests, the unit
must be correctly connected to the test equipment.
Recommended equipment: RS232 data cable (NKN6560A) or USB data cable (NKN6559A) and a
PC computer workstation with RSS installed.
NOTE: For a list of recommended programming equipment, applicable part numbers, and
descriptions, refer to Appendix A: Ordering Replacement Parts and Kits.
To connect the unit to a PC using the iDEN RS-232 (serial) or USB data cable