VR 103 (Lch)
VR 104 (Reh)
VR 101 (Lch)
VR 102 (Rch)
Adjustment value
ee
|
1. Bias Oscillator Adjustment
Play the 315 Hz/0 dB
section of the STD-331E
test tape.
TP. 1 (Lch)
TP. 2 (Rch)
Load the STD-610 test
tape with no input signal.
VR651 (Lch) * 1
VR653 (Lch) *2
Repeatedly record, playback
VR652 (Reh) *1
VR654 (Rch) *2
LINE OUT
VR653 (Lch)
VR654 (Reh)
* 1: CT-W701R only
and adjust so that the
* 2: CT-W801R, W851R
only; Adjust VR653, VR654 of DECK I with the REC (1) UNIT of DECK i, and adjust those of
DECK II with the REC (2)U NIT of DECK I!
Record the 315 Hz and
8.3 kHz signals at -26 dBV
input level and playback.
(STD-631)
plyaback level of 6.3 kHz
signal becomes 0 dB + 0.5
dB when compared with the
315 Hz signal.
33