Page 1
Therma V Monobloc, R290 MFL66101130 Region : EU Published on Nov. 02, 2023...
Page 2
Therma V General Information Model Line Up...
Page 3
Therma V General Information 1. Model Line Up Capacity Index Product Chassis Model Name FHNW16606C0 [HN1616HC NK0] Hydro Unit FHNW16809C0 [HN1639HC NK0] Capacity Index Product Phase Chassis Model Name 12.0 FHBW126B0 [HM121HF UB60] 14.0 FHBW146B0 [HM141HF UB60] 16.0 FHBW166B0 [HM161HF UB60] Monobloc UN60B FHBW098X0 [HM093HF UB60]...
Page 5
Hydro Unit 1. Specifications 2. List of Functions 3. Accessory Compatibility List 4. Dimensions 5. Piping Diagrams 6. Wiring Diagrams...
Page 6
Hydro Unit Product Data 1. Specifications 1.1 Product FHNW16606C0 [HN1616HC NK0] Category Unit Specification Major Minor Classification Chassis Cooling(min. ~ max.) ℃(DB) 5~27 Operation range(Leaving Water) Heating(min. ~ max.) ℃(DB) 15~75 Domestic hot water(min. ~ max.) ℃(DB) 15 ~ 80* Power supply Case 1 V, Φ, Hz...
Page 7
Hydro Unit Product Data 1. Specifications FHNW16809C0 [HN1639HC NK0] Category Unit Specification Major Minor Classification Chassis Cooling(min. ~ max.) ℃(DB) 5~27 Operation range(Leaving Water) Heating(min. ~ max.) ℃(DB) 15~75 Domestic hot water(min. ~ max.) 15 ~ 80* ℃(DB) Power supply Case 1 V, Φ, Hz 220-230-240, 1, 50...
Page 8
Water Pressure Monitoring Thermostat Interface (230V AC) Thermostat Interface (24V AC) Digital Output For External Pump Digital inputs for energy saving (SG Ready) Communication with LG ESS by Modbus DHW(Domestic Hot Water) Tank Kit Solar thermal function Accessory(3rd party) Water Product functions...
Page 9
Hydro Unit Product Data 3. Accessory Compatibility List FHNW16606C0 [HN1616HC NK0], FHNW16809C0 [HN1639HC NK0] Category Accessory Name Model Name Description Compatibility Remote Controller Wired - RS3 (Standard III) PREMTW101 White Simple PDRYCB000 1 input port, AC 220 - 240V Dry Contact Communication PDRYCB320 8 input port, For 3rd Party Thermostat (Analog Input)
Page 10
Hydro Unit Product Data 4. Dimensions 4.1 Dimensional Drawing (External) FHNW16606C0 [HN1616HC NK0], FHNW16809C0 [HN1639HC NK0]...
Page 11
Hydro Unit Product Data 4. Dimensions 4.2 Dimensional Drawing (Internal) FHNW16606C0 [HN1616HC NK0], FHNW16809C0 [HN1639HC NK0]...
Page 12
Hydro Unit Product Data 5. Piping Diagrams FHNW16606C0 [HN1616HC NK0], FHNW16809C0 [HN1639HC NK0] : Heating inlet <Water Side> : Heating outlet <Indoor Unit> Air Vent Expansion Vessel Shut off Water Water * S13 : Electric backup heater outlet temp. sensor...
Page 13
Hydro Unit Product Data 6. Wiring Diagrams 6.1 Product FHNW16606C0 [HN1616HC NK0]...
Page 14
Hydro Unit Product Data 6. Wiring Diagrams FHNW16809C0 [HN1639HC NK0]...
Page 15
Monobloc 1. Specifications 2. List of Functions 3. . Accessory Compatibility List 4. Dimensions 5. . Piping Diagrams 6. Wiring Diagrams 7. . Performance Data 8. Operation Range 9. . Sound levels 10. . Hydraulic Performance...
THERMA V Monobloc Product Data 1. Specifications ■ Combination with Hydro Unit type (1Φ) Performance specifications FHBW126B0 FHBW146B0 Outdoor Leaving [HM121HF UB60] [HM141HF UB60] temp. water (°CDB) temp. (°C) 12.0 14.0 10.0 11.0 Heating 12.0 14.0 Capacity 11.8 13.0 10.3 11.5 12.0 Cooling...
Page 17
THERMA V Monobloc Product Data 1. Specifications FHBW126B0 FHBW146B0 Technical specifications [HM121HF UB60] [HM141HF UB60] Canned type for hot water Canned type for hot water Type circulation circulation GRUNDFOS, UPML GEO 20-105 GRUNDFOS, UPML GEO 20-105 Model (maker, name) CHBL CHBL Water pump*** Motor type...
Page 19
THERMA V Monobloc Product Data 1. Specifications FHBW166B0 Technical specifications [HM161HF UB60] Type Canned type for hot water circulation Model (maker, name) GRUNDFOS, UPML GEO 20-105 CHBL Motor type BLDC Water pump*** Steps of pumping performance Variable speed 10% to 100% Min.~Max.
Page 20
THERMA V Monobloc Product Data 1. Specifications ■ Combination with Hydro Unit type (3Φ) Performance specifications FHBW098X0 FHBW128B0 Outdoor Leaving HM093HFX UB60 [HM123HF UB60] temp. water (°CDB) temp. (°C) 12.0 10.0 Heating 12.0 Capacity 11.8 11.5 Cooling 10.5 1.84 2.55 2.81 3.23 Heating...
Page 21
THERMA V Monobloc Product Data 1. Specifications FHBW098X0 FHBW128B0 Technical specifications HM093HFX UB60 [HM123HF UB60] Canned type for hot water Canned type for hot water Type circulation circulation GRUNDFOS, UPML GEO 20-105 GRUNDFOS, UPML GEO 20-105 Model (maker, name) CHBL CHBL Water pump*** Motor type...
Page 23
THERMA V Monobloc Product Data 1. Specifications FHBW148B0 FHBW168B0 Technical specifications [HM143HF UB60] [HM163HF UB60] Canned type for hot water Canned type for hot water Type circulation circulation GRUNDFOS, UPML GEO 20-105 GRUNDFOS, UPML GEO 20-105 Model (maker, name) CHBL CHBL Water pump*** Motor type...
THERMA V Monobloc Product Data 2. List of functions FHBW098X0 [HM093HFX UB60] FHBW126B0 [HM121HF UB60] FHBW128B0 [HM123HF UB60] Category Functions FHBW146B0 [HM141HF UB60] FHBW148B0 [HM143HF UB60] FHBW166B0 [HM161HF UB60] FHBW168B0 [HM163HF UB60] Defrost / Deicing High pressure switch Low pressure switch Reliability Phase protection Restart delay (3-minutes)
Page 25
THERMA V Monobloc Product Data 3. Accessory Compatibility List FHBW126B0 [HM121HF UB60] FHBW146B0 [HM141HF UB60] FHBW166B0 [HM161HF UB60] Category Product Remark FHBW098X0 [HM093HFX UB60] FHBW128B0 [HM123HF UB60] FHBW148B0 [HM143HF UB60] FHBW168B0 [HM163HF UB60] AC EZ PQCSZ250S0 AC EZ AC Ez Touch PACEZA000 AC Ez Touch Central...
Page 26
THERMA V Monobloc Product Data 4. Dimensions...
THERMA V Monobloc Product Data 5. Wiring Diagram ■ Internal Diagrams (1Φ)
Page 28
THERMA V Monobloc Product Data 5. Wiring Diagram ■ Internal Diagrams (3Φ)
Page 29
THERMA V Monobloc Product Data 5. Wiring Diagram ■ Field Wiring For Hydro Unit type Water Water In Switch box Name Name Hydro unit DHW tank * Outdoor unit Power supply DHW boost heater * Communication cable DHW tank kit * Heating water pipes Circuit breaker for DHW boost heater * Remote controller...
THERMA V Monobloc Product Data 7. Capacity Tables FHBW126B0 [HM121HF UB60], FHBW128B0 [HM123HF UB60] Water flow rate 34.5 LPM Water flow rate 21.6 LPM Water flow rate 17.3 LPM Outdoor LWT 30 °C LWT 35 °C LWT 40 °C LWT 45 °C LWT 50 °C LWT 55 °C...
Page 33
THERMA V Monobloc Product Data 7. Capacity Tables FHBW146B0 [HM141HF UB60], FHBW148B0 [HM143HF UB60] Water flow rate 40.3 LPM Water flow rate 25.2 LPM Water flow rate 20.1 LPM Outdoor LWT 30 °C LWT 35 °C LWT 40 °C LWT 45 °C LWT 50 °C LWT 55 °C...
Page 34
THERMA V Monobloc Product Data 7. Capacity Tables FHBW166B0 [HM161HF UB60], FHBW168B0 [HM163HF UB60] Water flow rate 46.0 LPM Water flow rate 28.8 LPM Water flow rate 23.0 LPM Outdoor LWT 30 °C LWT 35 °C LWT 40 °C LWT 45 °C LWT 50 °C LWT 55 °C...
Page 35
THERMA V Monobloc Product Data 7. Capacity Tables 7.2 Cooling Operation ■ Maximum Capacity FHBW098X0 [HM093HFX UB60] Water flow rate 25.9 LPM Outdoor Temperature LWT 7 °C LWT 10 °C LWT 13 °C LWT 15 °C LWT 18 °C LWT 20 °C LWT 22 °C [°C DB]...
Page 36
THERMA V Monobloc Product Data 7. Capacity Tables FHBW126B0 [HM121HF UB60], FHBW128B0 [HM123HF UB60] Water flow rate 33.1 LPM Outdoor Temperature LWT 7 °C LWT 10 °C LWT 13 °C LWT 15 °C LWT 18 °C LWT 20 °C LWT 22 °C [°C DB] 11.50...
Page 37
THERMA V Monobloc Product Data 7. Capacity Tables FHBW146B0 [HM141HF UB60], FHBW148B0 [HM143F UB60] Water flow rate 34.5 LPM Outdoor Temperature LWT 7 °C LWT 10 °C LWT 13 °C LWT 15 °C LWT 18 °C LWT 20 °C LWT 22 °C [°C DB] 12.00...
Page 38
THERMA V Monobloc Product Data 7. Capacity Tables FHBW166B0 [HM161HF UB60], FHBW168B0 [HM163HF UB60] Water flow rate 35.9 LPM Outdoor Temperature LWT 7 °C LWT 10 °C LWT 13 °C LWT 15 °C LWT 18 °C LWT 20 °C LWT 22 °C [°C DB] 12.50...
Page 39
THERMA V Monobloc Product Data 8. Operation Limits 8.1 Heating Hea ng - 28 Hea ng - 28 Note • DHW operation without electric heater : max. 65 °C • DHW operation with electric heater : max. 80 °C...
Page 40
THERMA V Monobloc Product Data 8. Operation Limits 8.2 Cooling Cooling Cooling...
THERMA V Monobloc Product Data 10. Hydraulic Performance The water pump is variable type which is capable to change flow rate, so it may be required to change default water pump capacity in case of noise by water flow. In most case, however, it is strongly recommended to set capacity as Maximum.
Page 46
THERMA V Monobloc Product Data 10. Hydraulic Performance ■ GRUNDFOS Water Pump (UPML 20 - 105 CHBL) 100% Note Performance test based on standard ISO 9906 with pre-pressure 2.0 bar and liquid temperature 20°C. ■ OH SUNG Water Pump (ODM - 061P) Q-H Chart 100% Q [LPM]...
Page 48
Installation of Outdoor Unit Installation 1. Information for Refrigerant ■ Refrigerant _ R290 • The refrigerant R290 has a lower GWP(Global Warming Potential)value than R32. The Ozone Depletion Potential (ODP) of R290 is 0, and Global Warming Potential(GWP) is 3. •...
Page 49
Installation of Outdoor Unit Installation 2. Selection of the best Location 2.1 Best location • The outdoor unit is installed outside to exchange heat with ambient air. • Therefore, it is important to secure proper space around the outdoor unit and care for specific external conditions. This chapter presents a guide to install the outdoor unit, make a route to connect with the indoor, and what to do when installed around seaside.
Page 50
Installation of Outdoor Unit Installation 2. Selection of the best Location 2.2 Safety zone Since the outdoor unit contains flammable refrigerant, a separate safety zone must be defined near the outdoor unit. • Special safety precautions must be taken within the areas marked below. •...
Page 51
Installation of Outdoor Unit Installation 2. Selection of the best Location 2.3 Lifting method Sub line 40º or less Intake hole Air outlet grille Corner Always hold the unit by the corners, as holding it by the side intake holes on the casing may Forklift cause them to deform.
Page 52
Installation of Outdoor Unit Installation 3. Foundation for Installation • Check the strength and level of the installation ground so that the unit will not cause any operating vibration or noise after installation. • Fix the unit securely by means of the foundation bolts. Prepare 6sets of M12 foundation bolts, nuts and washers available on the market.
Page 53
Installation of Outdoor Unit Installation 4. Water Control 4.1 Water quality Water quality should be complied with EN 98/83 EC Directives. <!> IMPORTANT • If the product is installed at existing hydraulic water loop, it is important to clean hydraulic pipes to remove sludge and scale. •...
Page 54
Installation of Outdoor Unit Installation 4. Water Control 4.2 Frost protection ■ Freezing Protection • In areas of the country where entering water temperatures drop below specified temperature, the water pipe must be protected by using an approved antifreeze solution. - For Medium Temperature : below 15℃...
Page 55
Installation of Outdoor Unit Installation 4. Water Control 4.3 Capacity correction factor by antifreeze If a antifreeze is used, pressure drop and capability degradation of the system can be occurred. Refer to the next table. Antifreeze % by wt Antifreeze Type Correction Factor Item Cooling Capacity 0.998...
Page 56
Installation of Outdoor Unit Installation 5. Water Piping System 5.1 Water piping and water circuit connection ■ General Considerations Followings should be considered before beginning water circuit connection • Service space should be secured. • Water pipes and connections should be cleaned using water. •...
Page 57
Copyright 2023 LG Electronics Inc. All Rights Reserved. The air conditioners manufactured by LG have received ISO9001 certificate for quality assurance and ISO14001 certificate for environmental management system. The specifications, designs, and information in this brochure are subject to change without notice.