2) SUB installation (right bottom)
* Remove the two-pin connector (with leads) from
the TSU-5.
Caution:
oe
Keep the two-pin connector (with leads) for later
¢ Remove the protective sheet from the pad and at-
tach it to the TSU-5.
Caution: -
-
wie
Attach as shown in the accompanying illustration.
* Remove the two-pin jumper plug from CNY,
¢ Plug the seven-pin connector (with leads) from the
IF unit onto the TSU-5. Connect the TSU-5 to CN9
using the two-lead cable provided.
Caution:
Keep the two screws provided with the TSU-5 for
later use, They are not needed now.
Two-lead
cable
3. Replace the bottom cover.
Note:
Avoid
catching your fingers and wiring harness
when closing.
7-3.
UT-10 1200MHz UNIT INSTALLATION
Note:
.——---_-—_—_...
-»--
The UT-10 is not available in some areas.
1, Remove the top and bottom covers of the trans-
ceiver. Refer to Section
6-6-1.
2. Remove five bushings fram the top cover using di-
agonal cutters (Refer to figure A).
3. Remove the sub panel from the rear of the chassis
as shown in Fig. B.
Caution:
_
Keep the two screws removed for later use. They
are not needed now.
sub panel
4. Attach the 18-pin connector and the 11-pin con-
nector from the UT-10 as shown in Fig. C.