Philips 5000 Service Manual page 41

Hide thumbs Also See for 5000:
Table of Contents

Advertisement

PHI 5000
When the Steam-Out is complete the following parameters are reset to their default values
Parameters
Espresso_pulses_qty
EspressoLungo_pulses_qty
Classic_Coffee_pulses_qty
Cappuccino_pulses_qty
Cappuccino_milk_brew_time
Lattemacchiato_pulses_qty
Lattemacchiato_milk_brew_
time
Americano_pulses_qty
FrothMilk_milk_brew_time
Coffee_Grinder
Alarm_Refill
Bu_Loaded
Aroma_Espresso
Aroma_Drip
TimeSleep
Filter_Present
Once entered the Steam Out mode the display shows the "STEAM OUT" indi-
ERROR: The number remains 0 or the grinder does not run, the display
cation. Buttons can be released.
backlight changes from white to red; check the Grinder and the wiring
from the Grinder to the CPU/POWER board (JP8)
IMPORTANT NOTE: to execute the Steam-out procedure the Ntc sensor
must work correctly; if some errors occurs on Ntc during the steam-out, the
Check the temperature
procedure can't continue and an error message is shown on the display.
The number shows the heater temperature
IMPORTANT NOTE: to execute the Steam-Out procedure the DREGDRAWER
must be in place and the DOOR must be closed.
ERROR: In the indication HEATER appears "SHORT", the NTC tempera-
If these 2 conditions are not respected a warning message is shown on the
ture-sensor is shorted, the display backlight changes from white to red;
display and the Steam-Out is interrupted.
check the wiring from the NTC temperature-sensor to the CPU/POWER
The machine starts the Steam Out and in the display appears the indication
board (JP13).
"ON".
While the Steam Out runs the Electro valve is opened and water comes out
ERROR: In the indication HEATER appears "OPEN", the NTC temper-
the Water/Steam pipe.
ature-sensor is detached or broken, the display backlight changes from
white to red; check the wiring from the NTC temperature-sensor to the
When the Steam Out is complete the message "COMPLETE" is shown on
CPU/POWER board (JP13).
the Display.The Electro valves automatically closes and the machine can be
switched off.
Press the Z1 button to switch on the Heater
The absorbed current ( Amperometer on the main supply) is OK, the indi-
cation HEATER changes from "OFF" to "ON" and the temperature starts
increasing.
Default value
145
If temperature is over 100°C, the backlight change from WHITE to
345
RED. This is a ALERT message to avoid heating the HEATER element over
500
dangerous temperature.
170
ERROR: the absorbed current is KO or the temperature does not
increase; check the wiring from the heater to the CPU/POWER
340
board (JP19) and the wiring of the NTC temperature-sensor (JP13).
120
400
150
340
0
TRUE
FALSE
3 Beans
4 Beans
15 minutes
FALSE
Length "Espresso" product
Length "Espresso Lungo" product
Length "Classic coffee" product (not used in PHI5000
machine)
Length "Cappuccino" product – Number of flow meter
impulses during coffee cycle
Length "Cappuccino" product – Time of milk
brewing (x100ms)
Length "Latte Macchiato" product – Number of flow
meter impulses during coffee cycle
Length "Latte Macchiato" product – Time of milk
brewing (x100ms)
Length "Americano" product
Length "Froth Milk" product – Time of milk
brewing (x100ms)
Number of grounds in dregs drawer
Request priming circuit next power-on of the machine
Set Brew-unit clean and not fill with coffee
Aroma for high pressure products
Aroma for low pressure products (not used in
to machine)
Timer for enter in stand-by from normal mode
Presence of Brita filter in machine (not used in Incanto
machine)
04 DIAGNOSTIC MODE
Description
Incan-
9/8

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents