NEC Express5800/R120i-2M Installation Manual page 97

Hide thumbs Also See for Express5800/R120i-2M:
Table of Contents

Advertisement

Chapter 3 Appendix
Source
ID
Timing when an event is logged
Windows Server 2019
"System Log"
Kernel-PnP
219
When installing an OS with Rapid Setup
Kernel-PnP
225
When applying
Standard Program Package
Microsoft-Windows-Hyper-V-
VmSwitch
260
When starting system, or starting virtual
machine
icea
262
When SFP+/SFP28 module (N8104-189/
190) or DA cable disconnected from
optional LAN board (N8104-208/212).
icea
272
When SFP+/SFP28 module (N8104-189/
190) or DA cable is connected to the LAN
board (N8104-208/212) and the network
link is down.
Applying Standard Program Package.
Service Control Manager
7023
When running an OS for the first time
Service Control Manager
7023
When installing an OS
Level
Message (Description)
Action
The driver \Driver\q57nd60a failed to load for the device
Warning
PCI\VEN_xxxx&DEV_xxxx&SUBSYS_xxxxxxxxxxxx.
* x is a different display name depending on the LAN board.
This event does not affect system operation.
The application YYY with process id XXX stopped the removal or
ejection for the device ZZZ.
Warning
* ZZZ : Instance name of the device
YYY : Name of the process that was using the device
XXX : ID of the process that was using the device
This event does not affect system operation.
Failed to move RSS queue xx from VMQ xx of switch
xxxxxxxx-xxxx-xxxx-xxxx-xxxxxxxxxxxx (Friendly Name: xx),
Error
ndisStatus = -1071448015 .
This event does not affect system operation.
Intel(R) Ethernet Network Adapter E810-XXV-2 xxx
PROBLEM: Module is not present.
Possible Solution(s):
Manually set the speed/duplex or use Intel(R) Ethernet Port
Error
Configuration Tool to change the port option.
If the problem persists, use a cable/module that is found in the
supported modules and cables list for this device.
* "x" depends on the optional LAN board environment.
Confirm the SFP+/SFP28 module (N8104-189/190) or DA cable.
Intel(R) Ethernet Network Adapter E810-XXV-2 xxx
PROBLEM: A parallel fault was detected.
Error
Possible Solution: Change link partner connection and configuration.
* x is a different display name depending on the LAN board.
This event does not affect system operation.
"xxxxxxxx service terminated with the following error:
Error
A device attached to the system is not functioning."
This event does not affect system operation if it is recorded only on
the first startup and not recorded repeatedly.
The Spooler service terminated with the following error:
Error
Ran out of memory
There is no problem when it occurs at following conditions.
1. Occurs once during OS installation, and it does not register
continuously.
2. After sign-in to the system, the service started normally.
Installation Guide (Windows Server 2019)
1. List of Windows Event Logs
97

Advertisement

Table of Contents
loading

Table of Contents