Technical Data
Control Panel Interface
Voltage supply for outputs, load voltage supply and internal logic circuitry
Voltage supply
rated value
permissible range
value at t < 0.5 sec
Power consumption of logic circuitry
Short-circuit protection upon polarity rever-
sal of load voltage
Connection of
Outputs
No. of outputs
in groups of
output DO1 to DO4
output DO5 to DO8
output DO9 to DO12
output DO13 to DO16
Optical isolation
Output voltage
with signal "0"
with signal "1"
Output current
with signal "0"
with signal "1"
Switch rate at
resistive load
lamp load
Load current per group
aggregate current
on short-circuit
Cable length
Voltage supply for inputs
Voltage supply
rated value
permissible range
value at t < 0.5 sec
Connection of
A-6
OP37 24 V DC
+18.0 to +30.0 V
35 V
40 mA
Lamps (inductive load not permitted)
16
4
Group 1
Group 2
Group 3
Group 4
–
Max. 2 V (idling)
Min. (voltage supply –3 V)
Max. 1 mA
Max. 500 mA per group
1 output of 200 mA, the remainder 100 mA
Max. 100 Hz
Max. 8 Hz
500 mA
Complete group deenergized
Max. 1 m
+ 24 V DC
+18.0 to +30.0 V
35 V
Pushbuttons, switches (inductive load not permitted)
TP27, TP37 Equipment Manual