2. INSTALLATION AND PREPARATIONS FOR USE
Adjusting the reduced flame position:
The flame length in the minimum position is adjusted with a flat screw located on the valve. For
valves with flame failure device, the screw is located on the side of the valve spindle(Figure 12). For
valves without flame failure device, the screw is located inside the valve spindle(Figure 13). For
easier reduced flame adjustment, it is advised to remove the control panel (and microswitch, if
present) during adjustment.
To determine the minimum position, ignite the burners and leave them on in minimum position.
Remove the with the help of a small screwdriver fasten or loosen the bypass screw around 90
angular degrees. When the flame has a length of at least 4mm, the gas is well distributed. Make
sure that the flame does not die out when passing from the maximum position to the minimum
position. Create an artificial wind with your hand toward the flame to see if the flames are stable.
Valve with flame failure device
Bypass Screw
For oven burner, operate the oven burner at minimum position for 5 minutes, then open and close
the oven door for 2-3 times to check the flame stability of the burner.
Reduced flame position adjustment is not required for grill burners.
The position the bypass screw must be loosened for conversion from LPG to NG. For conversion
from NG to LPG, the same screw must be fastened. Make sure that the appliance is unpluged from
the electric mains and the gas supply is open.
Thermostatic oven valve
Bypass Screw
Figure 10
Figure 12
12
Valve without flame failure device
Screw(inside the hole)
Non-thermostatic oven valve
Bypass Screw
Figure 11
Figure 13