WARNING: FIRE OR EXPLOSION HAZARD
 The furnace is designed and approved for use with Natural
Gas and Propane Gas (LP) ONLY.
 DO NOT BURN ANY LIQUID FUEL OR SOLID FUEL IN THIS
FURNACE.
 Burning any unapproved fuel will result in damage to
the furnace's heat exchanger, which could result in Fire,
Personal Injury, and/or Property Damage.
WARNING:
 This product can expose you to chemicals including Lead
and Lead components, which are known to the State
of California to cause cancer and birth defects or other
reproductive harm. For more information go to
P65Warnings.ca.gov.
WARNING: FIRE, EXPLOSION, ELECTRICAL SHOCK, AND
CARBON MONOXIDE POISONING HAZARD
 Failure to follow this warning could result in dangerous
operation, serious injury, death, or property
damage.  Improper installation, adjustment, alteration,
maintenance, or use could cause carbon monoxide
poisoning, explosion, fire, electrical shock, or other
conditions which may cause personal injury or property
damage. Consult a qualified service agency, local gas
supplier, or your distributor for information or assistance.
WARNING: FIRE HAZARD
 The furnaces must be kept free and clear of insulating
materials. Inspect surrounding area to ensure insulation
material is at a safe distance when installing furnaces or
adding insulation materials. Insulation materials may be
combustible.
See Section 3, Fig. 3 as seen in the Installation, Operation, and
Maintenance Manual for required clearances to combustible
construction.
Maintain a 1 in. clearance from combustible materials to supply
air ductwork for a distance of 36 in. horizontally from the
furnace. See NFPA 90B or local code for further requirements.
 These furnaces SHALL NOT be installed directly on
carpeting, tile, or any other combustible material other than
wood flooring.
Bosch Thermotechnology Corp. | 11.2018
www.
Bosch 96% AFUE Gas Furnace | 5
WARNING: CARBON MONOXIDE POISONING HAZARD
 Failure to follow instructions could result in severe personal
injury or death due to carbon-monoxide poisoning, if
combustion products infiltrate into the building.
 Check that all openings in the outside wall around the vent
(and air intake) pipe(s) are sealed to prevent infiltration of
combustion products into the building.
 Check that furnace vent (and air intake) terminal(s) are not
obstructed in any way during all seasons.
CAUTION:
 Before heating season begins, a qualifi ed installer or service
agency must examine the furnace to ensure that:
1.
All fl ue gas carrying areas external to the furnace
(i.e. chimney, vent connector) are clear and free of
obstructions.
2.
The vent connector is in place, slopes upward and
is physically sound without holes or exccessive
corrosion.
3.
The return-air duct connection(s) is physically sound,
is sealed to the furnace cabinet, and terminates
outside the space containing the furnace.
4.
The physical support of the furnace is sound without
sagging, cracks, gaps, etc around the base so as to
provide a seal between the support and the base.
5.
There are no obvious signs of deterioration of the
furnace.
6.
The burner fl ames are positioned correctly by
comparing with pictorial sketches of the main burner
fl ame (see Section 12, Fig 42 in the Installation,
Operation, and Maintenance Manual).
WARNING: FIRE, EXPLOSION
 Should the gas supply fail to shut off or if overheating
occurs, shut off the gas valve to the furnace before shutting
off the electrical supply.
WARNING:
 Furnace operation requires air for combustion and
ventilation. Do not block or obstruct air openings on furnace
or spacing around furnace required for supplying sufficient
combustion air and ventilation.