Technical Information
5.1.1
Retaining Clips Mounting
Figure 5-1: Retaining Clip Mounted without Combi-Set Installed
Removal Procedure
Refer to Figure 5-2.
1. Shut off the electrical supply to the appliance (i.e. shut off the
circuit breaker).
2. Disconnect the electrical supply.
3. Access the underside of the appliance.
4. Press inward on the retaining clips (1) while pushing the
appliance upward (2)
Figure 5-2: Removal of Combi-Set from Retaining Clips.
KM400 Series Combi-Sets
32