Serial Outputs - Bosch PST 6101.321 Technical Information

Timer and i/o level
Table of Contents

Advertisement

7.3.2

Serial outputs

1070 080 056-101 (99.09) GB
PST 6101.321 / PSI 6101.321
The outputs are driven via the serial Interbus-S interface. The status word has the follow-
ing structure:
Bit
Outputs of the PSI 6101.321 / PST 6101.321 according to the enhanced C0
profile, Messrs. Bosch
0
<Weld complete>
1
<Tipdress request> (tip dress inquiry)
2
<Prewarning>
3
<End of Stepper> reached
4
<Control ready>
5
<Welding fault>
6
<Without weld process monitoring>
7
<Weld> (with welding current)
8
not used
9
not used
10 not used
11
not used
12 not used
13 not used
14 not used
15 not used
Electrical connection
7-31