Appendix C — Default/Reset Procedure
If the SIMATIC MV340 locks up or becomes unresponsive, or if you would like to clear all
configuration and programming from the imager, follow the procedure below.
Important: The following procedure will clear the buffer, default configuration, and XML
programming, including Preamble and Postamble.
1. Unplug the SIMATIC MV340 from the PC.
2. While holding down the trigger, plug the reader into the USB port on the PC. You will
hear five rapid beeps.
3. Let go of the trigger after the five rapid beeps. The imager is now in Boot Mode.
4. Hold down the trigger again for approximately five seconds until it reboots. The imager
will vibrate first and then beep several times.
5. The imager should now operate in default mode. Save the default settings by reading
this symbol: