Console programs do not start
• Perform Keypad test in Maintenance mode
• If you cannot access the test, and the keys seem to have no a ect
when pressed, then the keypad has malfunctioned.
Program starts but no data registers when bike is pedaled
• Check that the connectors are properly seated in the back of the
consoles.
• Perform the Sensor tests in Maintenance mode. If one of the sen-
sors does not work it needs replacement. If both sensors do not
work then it could be a bad console or both sensors are bad.
Symmetry measurement is incorrect
• Perform the sensor tests in Maintenance Mode
• If sensors are functioning then perform Crank Position Calibration
• If calibration is ok then check the Unit Type is set to 7.0 U.
Pedal resistance seems harder/di erent than before
Check the watts per level setting in the Set Up menu (see page 22).
The default setting from the factory is 5 watts per level..
Clicking noise when pedaling
• Make sure the pedal is tightened properly. It is common to have to
retighten the pedal after the rst few hours use.
• Make sure the adjustment knob for the pedal slide is tightened as
much as possible.
• Check that the leveling feet on the bottom of the bike are adjusted
properly.