Technical data
11.1 Technical specifications of SIMATIC MV500
Operating distance
Mounting type of lens
Type of light source
Image acquisition frequency (max.)
Type of focusing
Supply voltage, current consumption, power loss
Supply voltage
Current consumption (at 24 V DC)
Mechanical specifications
Housing
Permitted ambient conditions
Ambient temperature
Relative humidity (max.)
Degree of protection
Shock resistance
Shock acceleration
Vibration acceleration
Design, dimensions and weight
Dimensions (W × H × D)
Weight
Type of mounting
LED display design
196
Typical
Maximum
Material
Color
During operation
During transportation and storage
Mini lens:
70 ... 3000 mm
1)
EF lens:
Depending on the lens used
C-mount lens connection
Built-in ring lights or external ring lights
Device version S: 100 Hz
Device version H: 33 Hz
Mini-lens: Manual adjustment on the lens
EF lens: Automatic setting via WBM
24 V DC (20.4 to 28.8 V DC)
0.2 A
0.4 A with ring light (continuous light)
2.0 A
Die-cast aluminum (silicone-free)
TI-Grey
0 ... +50 °C
-30 ... +70 °C
95%
IP67 according to IEC 60529
IEC 60068-2
300 m/s²
40 m/s²
68 × 122 × 45 mm
0.55 kg
4 x M4 screws
7 LEDs
Operating Instructions, 05/2019, C79000-G8976-C494-02
6GF3540-0xx10
6GF3550-0xx10
2)
SIMATIC MV500