HP 16501A User Manual page 63

Logic analysis system
Hide thumbs Also See for 16501A:
Table of Contents

Advertisement

Intermodule Measurements
To adjust for minimum skew between two modules involved in an intermodule
measurement
Record the differences shown by the two modules.
8
You can use the X and O markers to measure the differences in delays.
Select the Intermodule Menu.
9
Select Skew, then enter a skew correction value for one of the
10
modules using the knob or the keyboard.
Return to the module waveform display and recheck the skew
11
adjustment.
You will need to repeat steps 7 through 11 as needed until the trigger events
on the two waveforms match as closely as possible.
Before making an intermodule measurement, you should remove skew between
the modules to ensure that a simultaneous arm signal to both modules results in
captures of the same events around the trigger.
Skew Removal Between Timing Analyzer and Oscilloscope
2–28

Advertisement

Table of Contents
loading

This manual is also suitable for:

16500c

Table of Contents