Insert communication cable of indoor unit to the connector CN41 on PCB of the
Leak Detector, Confirm the terminal number of indoor unit and connect the Leak Detector
cable correctly. (The Leak Detector may be damaged if connecting the power supply of
indoor unit.)
If connect the Leak Detector to external device, communication cable of those is inserted
to the connector CN64 or CN65.
Gather the cable wire and
store to this space.
* Do not touch, damage, or dirty the top of sensor. It may cause that detecting performance is decreased.
5
Mount the Leak Detector body to rear cover. And be careful not to pinch the cable among
the body and rear cover.
Finally, tighten the bind screw to body.
*When mount Leak Detector body to rear cover, take care not to pinch connecting cable among body and rear cover.
Connecting cable
Leak Detector body
Bind screw