4.
Disconnect the power supply wiring from the terminal block. Alternatively, for convenience, remove the
terminal block with the wiring still connected and set it aside to be connected later to the new module.
5.
Install a new or blank module to prevent the ingress of dust and dirt.
Installing a Power Module
To install a power module, do the following:
1.
If equipped, remove the existing module.
2.
If applicable, connect the supplied terminal block to the module or connect the terminal block from the
previous module.
3.
Confirm or connect the wiring from the power supply to the module. For more information, refer to
Section 2.5, "Connecting
4.
Insert the module into the empty slot.
3
Figure 25: Installing a Power Module
1. Chassis    2. Power Module    3. Screws
5.
Hand-tighten the screws to secure the power module to the chassis.
6.
Turn on power to the device and confirm the module is receiving and supplying power. This is indicated by
the LEDs on the module.
LED
O
I
Installing/Removing Power Modules
Power".
1
2
State
Green
Green
The module is supplying power
The module is receiving power
Description
Chapter 4
Modules